Out-connect wired fittings
(see the following diagram)
1. CH2-GND, CH3-GND, CH4-GND
terminal----channel 2~4, connect wired
detector
’
s output terminal,
NOTE: switch
on power, there are about 45 seconds
for all out-connect wired zones to
enter stable state. After this time-delay,
the main will memorize all wired zones
on
“
not alarm
”
state.
(
attention: during
this 45sec time-delay, you should not
trigger any zone, otherwise the main
will memorize zones
’
being triggered
state to
“
not alarm
”
state falsely. If
memorize falsely, you can switch off
power and then switch on power to
re-memorize;
2.
“
+ALARM-
”
terminal----connect with
siren (voltage DC12V, current <800mA);
3.
“
-VCC+
“
terminal---power output terminal. That can supply power for wired detector,
but you should not use the
terminal for power supply as possible as you can;
The main
’
s Installation
⑴
At first you should select suitable installing position, the sensor
’
s sensitivity is
very high to human body
’
s moving breadthwise( like right fig.).And it is very low to
moving frontal. So when installing it , you should select a position that moving
object can move breadthwise to the sensor, so that the sensor lamp work reliably.
⑵
With screwdriver tighten off the bottom screw, and then insert a flat-screw into
middle slot and pull up it to open the front cover (fig 1).
⑶
Place the front cover with PCB on safe position avoiding other objects in.
⑷
On installing position mark installing hole, and then drill holes according to the
mark;
⑸
insert the standby power plug onto the standby power jack(see the 4 of the
interior PCB configure),put outer lines through outlet-line hole and connect line
according to out-connect wired fitting figure.
⑹
Fixing back cover on installing position according to fig.2;
⑺
Make front cover top aim at back cover top and close, then button up bottom and tighten the screw(fig 3).
★★★
warning: during you open the unit to install, do not touch the adjustable
inductance on PCB(see the
“
9
”
of the interior PCB configure), otherwise that
will effect the main
’
s receiving frequency and lead its receiving distance
become short. If you find the receiving distance is short, maybe you have
touched the inductance. Here we suggest the professional installation
person micro-adjust the inductance.
siren
+ -
1
3
O
N
P
U
L
S
E
L
E
D
O
F
F
-4
-6
0
4
2
-2
TAMPER
+
_
R ELA Y
wired detectorLX-AL6
_
12VDC+
RELAY
TAMPER
fig. 2
fig. 3
fig. 1
110
bread thw ise m ove,
se nsitivity hig h
frontal m ove,
sensitivity low
install
heigh t
2m ~2.5 m