Starting up the device - Configuration
Leuze electronic
BCL 604i
97
Parameter
Table 10.58:
Parameters for module 84 – Reference code comparison pattern
Parameter length
31 byte
Input data
None
Output data
None
10.15 Special Functions
10.15.1Module 90 – Status and control
This module supplies various device status information to the PROFIBUS master. Various functions of the
device can be controlled via the master's output data.
Parameter
None
Input data
Table 10.59:
Input data for module 90 – Status and control
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Code type compar
-
ison pattern 2
Specifies the type of the reference bar code.
0
UNSIGNED8
0: No code
1: 2/5 Interleaved
2: Code39
3: Code32
6: UPC, UPCE
7: EAN8, EAN13
8: Code128
10: EAN Addendum
11: Codabar
12: Code93
13: RSS-14
14: RSS Limited
15: RSS Expanded
0
-
Comparison pat
-
tern 2
Parameter string describing the content of the
reference bar code. Note: You can also use
the two placeholder characters that are stored
in the “Wildcard character” and “Don't care
character” parameters. If the string is empty,
no comparison takes place. If the most
recently stored character is the wildcard char
-
acter, the comparison is only carried out up to
the character before this wildcard character. In
this way it is possible to switch off a compari
-
son according to bar code length.
1
STRING
30 characters
null termi
-
nated
1 … 30 bytes of ASCII
characters
\00
-
The defined comparison pattern affects both reference code comparators (module 81 – refer
-
ence code comparator 1 and module 82 – reference code comparator 2).
Input data
Description
Addr.
Data type
Value range
Init value Unit
Reserved
Free
0.0
Bit
0
-
AutoRefl state
Signal state of the AutoRefl module
0.1
Bit
0: Reflector is recognized
1: Reflector is hidden
1
-
Auto Control result Indicates whether the result of the AutoControl
function was a good or bad reading.
0.2
Bit
0: Quality good
1: Quality bad
0
-