Menu description
Leuze electronic
BCL 604i
38
Table 8.3:
Digital SWIO submenu
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Sw. input/output 1
I/O mode
Input / Output / Passive
Determines the function of switching input/output 1.
In the case of passive, the connection is on 0 V if the
Inverted parameter is set to OFF, and on +UB if the
Inverted parameter is set to ON.
Input
Switching input
Invert
OFF / ON
OFF = activation of the switching input function upon high
level at the switching input
ON = activation of the switching input function upon low
level at the switching input
OFF
Debounce time
Value from 0 to 1000
Time in milliseconds for which the input signal must be
present and stable.
5
Start-up delay
Value from 0 to 65535
Time in milliseconds between the end of the debounce
time and activation of the function configured below.
0
Pulse duration
Value from 0 to 65535
Minimum activation time in milliseconds for the function
configured below.
0
Delay off time
Value from 0 to 65535
Time in milliseconds for which the function configured
below remains activated after the switching input signal is
deactivated and the pulse duration has expired.
0
Function
No BCL600i function
Reading gate start/stop
Reading gate stop
-Reading gate start
Teach reference code
Autoconfig start/stop
The function set here is carried out after the switching input
is activated.
Reading gate
start/stop