Starting up the device - Configuration
Leuze electronic
BCL 604i
96
Output data
None
10.14.3Module 83 – Reference code comparison pattern 1
Description
This module can be used to define the 1st comparison pattern.
Parameter
Table 10.57:
Parameters for module 83 – Reference code comparison pattern
Parameter length
31 byte
Input data
None
Output data
None
10.14.4Module 84 – Reference code comparison pattern 2
Description
This module can be used to define the 2nd comparison pattern.
Parameter
Description
Addr.
Data type
Value range
Default Unit
Code type compari
-
son pattern 1
Specifies the type of the reference bar code.
0
UNSIGNED8
0: No code
1: 2/5 Interleaved
2: Code39
3: Code32
6: UPC, UPCE
7: EAN8, EAN13
8: Code128
10: EAN Addendum
11: Codabar
12: Code93
13: RSS-14
14: RSS Limited
15: RSS Expanded
0
-
Comparison pattern
1
Parameter string describing the content of the
reference bar code. Note: You can also use
the two placeholder characters that are stored
in the “Wildcard character” and “Don't care
character” parameters. If the string is empty,
no comparison takes place. If the most
recently stored character is the wildcard char
-
acter, the comparison is only carried out up to
the character before this wildcard character. In
this way it is possible to switch off a compari
-
son according to bar code length.
1
STRING
30 characters
null termi
-
nated
1 … 30 bytes of ASCII char
-
acters
\00
-
The defined comparison pattern affects both reference code comparators (module 81 – refer
-
ence code comparator 1 and module 82 – reference code comparator 2).