Starting up the device - Configuration
Leuze electronic
BCL 604i
54
Parameter length
33 bytes
Input data
None
Output data
None
Notice on number of digits
If 0 is specified in a field for the number of digits, the corresponding parameter is ignored by the device
firmware.
Example:
Reading reliability
3
Min. reading reliability to be achieved in order
to output a read code.
23
UNSIGNED8
1 … 100
4
-
Check digit proce
-
dure 3
Used check digit procedure.
24.0…
24.6
BitArea
0: Standard check digit
evaluation
1: No check digit verifica
-
tion
2: MOD10 Weight 3
3: MOD10 Weight 2
4: MOD10 Weight 4_9
5: MOD11 Cont
6: MOD43
7: MOD16
0
-
Check digit output
3
Turns the check digit output on or off
24.7
Bit
Check digit output
0: Standard
1: Not standard
0
-
Code type 4
See code type 1
25.0 …
25.5
BitArea
See code type 1
0
-
Number-of-digits
mode 4
Specifies how the subsequent numbers of dig
-
its are to be interpreted.
26.6
Bit
0: Enumeration
1: Range
0
-
Digits 4.1
Decodable number of digits; in the case of a
range, this number defines the lower limit.
26.0 …
26.5
UNSIGNED8
0 … 63
0
-
Digits 4.2
Decodable number of digits; in the case of a
range, this number defines the upper limit.
27
UNSIGNED8
0 … 63
0
-
Digits 4.3
Decodable number of digits in the enumeration
mode.
28
UNSIGNED8
0 … 63
0
-
Digits 4.4
Decodable number of digits in the enumeration
mode.
29
UNSIGNED8
0 … 63
0
Digits 4.5
Decodable number of digits in the enumeration
mode.
30
UNSIGNED8
0 … 63
0
-
Reading reliability
4
Min. reading reliability to be achieved in order
to output a read code.
31
UNSIGNED8
1 … 100
4
-
Check digit proce
-
dure 4
Used check digit procedure.
32.0…
32.6
BitArea
0: Standard check digit
evaluation
1: No check digit verifica
-
tion
2: MOD10 Weight 3
3: MOD10 Weight 2
4: MOD10 Weight 4_9
5: MOD11 Cont
6: MOD43
7: MOD16
0
-
Check digit output
4
Turns the check digit output on or off
32.7
Bit
Check digit output
0: Standard
1: Not standard
0
-
a) Specifying a 0 for the number of digits means that this entry is ignored for the device.
Parameter
Description
Addr.
Data type
Value range
Default