Starting up the device - Configuration
Leuze electronic
BCL 604i
66
Parameter
None
Input data
Table 10.19:
Input data for modules 21 … 27
Input data
2 bytes consis 4..28 bytes of bar code information depending on the module
Output data
None
Remarks
The remarks for module 20 – decoder state, apply in an analogous manner. In addition, all bytes beginning
with address 1 are reset to the init. value.
Module
no.
Input data
Description
Addr.
Data type
Value range
Init val
-
ue
Unit
21 … 27
Reading
gate state
The signal indicates the current state of the
reading gate.
a)
0.0
Bit
0: Off
1: On
0
-
21 … 27
New result
Signal indicates whether a new decoding
result is present.
0.1
Bit
0: No
1: Yes
0
-
21 … 27
Result state Signal indicates whether the bar code has
been read successfully.
0.2
Bit
0: Successful reading
1: NOREAD
0
-
21 … 27
Further
results in the
buffer
Signal indicates whether further results are in
the buffer.
0.3
Bit
0: No
1: Yes
0
-
21 … 27
Buffer over
-
flow
Signal indicates that result buffers are occu
-
pied and the decoder rejects data.
0.4
Bit
0: No
1: Yes
0
-
21 … 27
New result
Toggle bit, indicates that a new decoding
result is present.
0.5
Bit
0->1: New result
1->0: New result
0
-
21 … 27
Result state Toggle bit indicates that the bar code has not
been read.
0.6
Bit
0->1: NOREAD
1->0: NOREAD
0
-
21 … 27
Waiting for
acknowl
-
edgement
This signal represents the internal state of the
control.
0.7
Bit
0: Base state
1: Control waiting for
acknowledgement from
the PROFIBUS master
0
-
21 … 27
Bar code
data length
Data length of the actual bar code informa
-
tion.
b)
1
UNSIGNED8
0-48
0
-
21
Data
Bar code information with a length of consis
-
tently 4 bytes.
2..
4x
UNSIGNED8
0-FFh
0
-
22
Data
Bar code information with a length of consis
-
tently 8 bytes.
2..
8x
UNSIGNED8
0-FFh
0
-
23
Data
Bar code information with a length of consis
-
tently 12 bytes.
2..
12x
UNSIGNED8
0-FFh
0
-
24
Data
Bar code information with a length of consis
-
tently 16 bytes.
2..
16x
UNSIGNED8
0-FFh
0
-
25
Data
Bar code information with a length of consis
-
tently 20 bytes.
2..
20x
UNSIGNED8
0-FFh
0
-
26
Data
Bar code information with a length of consis
-
tently 24 bytes.
2..
24x
UNSIGNED8
0-FFh
0
-
27
Data
Bar code information with a length of consis
-
tently 28 bytes.
2..
28x
UNSIGNED8
0-FFh
0
-
a) Attention: This does not necessarily correspond to the state at the time the bar code is scanned
b) If the bar code information (bar code and, possibly, other items such as the check sum) fits in the selected module
width, this value reflects the length of the transmitted data. A value larger than the module width indicates a loss of infor
-
mation caused by a module width which has been selected too small.