Starting up the device - Configuration
Leuze electronic
BCL 604i
50
1
Service, USB socket, type A
2
SW In/Out, M12 socket (A-coded)
3
Bus Out, M12 socket (D-coded)
4
Host/Bus In, M12 socket (D-coded)
5
PWR, M12 plug (A-coded)
Figure 10.1: Connections of the device
Check the applied voltage. It must be in the range b10V … 30 V DC.
Connecting functional earth FE
Ensure that the functional earth (FE) is connected correctly.
10.3 Setting the address
10.3.1 Setting the device address on the display
The device display has an important function for setting the PROFIBUS address. This is where the
PROFIBUS address is set, i.e. the respective station number of the network device.
The set address must be
³
0 and < 126. Each network device is thereby automatically informed that it is a
slave on the PROFIBUS with its specific address and that it is initialized and queried by the PLC.
The PROFIBUS permits an address range from 0 to 126. Address 126 must not be used for data commu
-
nication. It may only be used temporarily for commissioning. The default address is 126.
The address must be assigned separately for each bar code reader of type BCL 604i, which can be done
by entering on the display or using the webConfig tool.
In order to set the address via the display, proceed as follows:
In the main menu, select the Parameter menu.
Select the PROFIBUS menu item.
Press the enter button to enter the menu.
NOTICE
Unimpaired operation is only guaranteed when the functional earth is connected properly. All electrical
disturbances (EMC couplings) are discharged via the functional earth connection.
3
4
5
2
1
The address can only be set via the display if parameter enabling is active (see chapter 8.6).
The device does not allow address assignment via PROFIBUS!
Use the navigation buttons
to move through the menu. Activate the desired selection with
the enter button .