3.4.2 Manual configuration of the IP address
If your system does not include a DHCP server or if the IP addresses of the devices are to be set perma
-
nently, proceed as follows:
• Have the network administrator specify the data for IP address, net mask and gateway address of
the BCL 358
i
.
• Set the IP address manually via the BootP/DHCP server tool and deactivate the DHCP operation in
the BCL 358
i
. The BCL 358
i
automatically adopts these settings. A restart is not required.
Bild 3.4:
Manual configuration of the IP address
Alternatively, you can set the IP address manually via the webConfig tool. Proceed as follows:
• Have the network administrator specify the data for IP address, net mask and gateway address of
the BCL 358
i
.
• Connect the BCL 358
i
to your computer using the service cable.
• Set these values on the BCL 358
i
. Via webConfig:
Configuration
>
Communication
>
Ethernet interface
NOTE
If the IP address is set via the webConfig tool, then it becomes active after transfer to the device.
A restart is not required.