Commissioning and configuration
Leuze electronic GmbH + Co. KG
BCL 358
i
91
10.7.5 Class 107 - Result data
This class defines the transfer of the result data. The result data comes from the Formatter currently
selected. This can be selected and configured in WebConfig. This class also defines the output of frag
-
mented results. To occupy few I/O data, the results may be split into several fragments with this class. The
fragments can then be transmitted one after another with a handshake.
Object class 107 = 0x6B
Services:
• Get Attribute Single 0x0E
• Set Attribute Single 0x10
Activation status
Displays the current activation status.
0 Deactivated
1 Activated
User data or command
Distinction between result from the Formatter and answer from the command interpreter. Makes the
distinction easy for the user.
0 User data
1 Response from command interpreter
Further results in the buffer
This signal indicates whether further results are in the buffer.
0 No
1 Yes
Buffer overflow
This signal indicates that all result buffers are occupied and that the BCL 358
i
rejects data.
0 No
1 Yes
NOTE
The result is the data from the BCL 358
i
to the control.
Path
Designation
Size
in bit
Data type
Default
(dec)
Min.
(dec)
Max.
(dec)
Access
Cl.
Inst.
Attr.
107
1
1
Activation status
8
U8
0
0
1
Get
2
User data or
command
8
U8
0
0
1
Get
3
Further results in the buffer
8
U8
0
0
1
Get
4
Buffer overflow
8
U8
0
0
1
Get
5
New result (toggle bit)
8
U8
0
0
1
Get
6
Waiting for
acknowledgment
8
U8
0
0
1
Get
7
Result data length
16
U16
0
0
65,535
Get
8
Data
2048
U8 [256]
0
0
255
Get
9
Activate result fragmenta
-
tion
1)
1) This attribute is a parameter. The value of the parameter can be set via the configuration assembly.
8
U8
0
0
1
Set
10
Fragment number
8
U8
0
0
255
Get
11
Remaining
fragments
8
U8
0
0
255
Get
12
Fragment size
8
U8
32
0
255
Get