Commissioning and configuration
Leuze electronic GmbH + Co. KG
BCL 358
i
98
10.8.1 Example 1 - Activation & result
The following screenshot shows the configuration of the device in the RSLogix 5000 control software.
Figure 10.5: Configuration of example 1 - module definition with generic module
Figure 10.6: Configuration of example 1 - module definition with the EDS file
Structure of input assembly 100
Structure of output assembly 120
Structure of configuration assembly 190
Since the configuration is not used, the length of the configuration assembly is specified as 0. The device
then operates with the default values. In this case, the acknowledge mode is not used.
Inst.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
100
0
Device status
1
Number of results
2
Reserved
Waiting for
acknowledg
-
ment
New result
(toggle bit)
Buffer over
-
flow
Further
results in the
buffer
User data or
command
Status
activation
3
Result data length (low byte)
4
Result data length (high byte)
5
Data Byte 0
6
Data Byte 1
…
…
32
Data Byte 27
Inst.
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
120
0
Reserved
Standby
Error
acknowl
-
edge
Data
reset
Data
acknowledg
-
ment
Activation
signal