Online commands
Leuze electronic GmbH + Co. KG
BCL 358
i
112
Software reset
Code recognition
Command
’H’
Description
Carries out a software reset. The device is restarted and reinitialized, leaving it in the
same state as when the supply voltage is switched on.
Parameter
No
Acknowledg
-
ment
’S’ (start signal)
Command
’CC’
Description
Detects an unknown bar code and outputs number of digits, code type, and code infor
-
mation to the interface, without storing the bar code in the parameter memory.
Parameter
No
Acknowledg
-
ment
’xx yy zzzzzz’
xx:
Code type of the read code
’01’
2/5 Interleaved
’02’
Code 39
’03’
Code 32
’06’
UPC (A, E)
’07’
EAN
’08’
Code 128, EAN 128
’10’
EAN Addendum
’11’
Codabar
’12’
Code 93
’13’
GS1 DataBar OMNIDIRECTIONAL
’14’
GS1 DataBar LIMITED
’15’
GS1 DataBar EXPANDED
yy:
Number of digits of the read code
zzzzzz: Contents of the decoded label. A
appears if the label was not correctly read.