Technical data
Leuze electronic GmbH + Co. KG
BCL 358
i
48
5.5.12 Ink Jet (J) - optics: BCL 358
i
R1 J 100
Figure 5.23: "Ink Jet" reading field curve for line scanner with deflecting mirror
NOTE
Please note that the real reading distances are also influenced by factors such as labeling mate
-
rial, printing quality, scanning angle, printing contrast, etc., and may thus deviate from the
reading distances specified here.
Due to the shape of the optical laser spot, the CRT function may exhibit limitations (max. permis
-
sible tilt angle of ± 15°).
Low-contrast bar codes that are printed with inkjet should be sent to Leuze for examination.
0
50
150
250
400
550
750
350
100
200
300
450
650
500
700
600
50
100
300
250
150
200
-50
-100
-300
-250
-150
-200
BCL 3xx
i
R1 J 100
m = 0,5
m = 0,8
m = 0,5
m = 0,8
Reading distance [mm]
Re
adin
g field width [mm]