Display elements and display
Leuze electronic GmbH + Co. KG
BCL 358
i
69
Red, continuous light
Device error
- No bar code reading possible
NET LED
Off
NET LED off
- No voltage supply
- No IP address assigned
Flashing green
NET LED flashes green
- LED autotest for 0.25 s after power up
- No EtherNet/IP communication present
- BCL 358
i
is not assigned to a master
Green, continuous light
NET LED green
- BCL 358
i
Bus communication ok
Flashing red
NET LED flashes red
- LED function test for 0.25 s after power up
- Timeout in the bus communication
Continuous red light
NET LED red
- Double IP address
Flashing green/red
NET LED flashes green/red
- Self test
8.2
MS 358/MK358 LED indicators
=
Figure 8.2: MS 358/MK 358 - LED indicators
As a status display for the two Ethernet connections, Ethernet_0 and Ethernet_1, there are two split two-
colored LEDs each in the MS 358 and MK 358:
LED ACT0 / LINK0 (on the MS 358/MK 358)
Green, continuous light
Ethernet connected (LINK)
Yellow, flashing
Data communication (ACT)
LED ACT1 / LINK1 (on the MS 358/MK 358)
Green, continuous light
Ethernet connected (LINK)
Yellow, flashing
Data communication (ACT)
2 LEDs
MK 358
MS 358
2 LEDs
Ethernet 1 LED
(split, two-colored):
ACT1 / LINK1
Ethernet 0 LED
(split, two-colored):
ACT0 / LINK0
Ethernet 1 LED
(split, two-colored):
ACT1 / LINK1
Ethernet 0 LED
(split, two-colored):
ACT0 / LINK0