Technical data
Leuze electronic
RSL 410
88
Table 15.4:
Protective field range
Table 15.5:
Warning field data
Table 15.6:
Measurement field data
Table 15.7:
Electrical supply
Device range
S
M
L
XL
Resolution [mm]
Protective field range [m]
150
3.00
4.50
6.25
8.25
70
3.00
4.50
6.25
8.25
60
3.00
4.50
6.25
8.25
50
3.00
4.50
6.25
6.25
40
3.00
4.50
4.50
4.50
30
3.00
3.50
3.50
3.50
Number of field pairs
1, 10, 10 + 10, 100
Warning field range
0 - 20 m
Object size
150 mm x 150 mm
Diffuse reflectance WF minimum
Min. 10 %
Detection range
0 - 50 m
Diffuse reflectance
20 %
Radial resolution
5 mm
Lateral resolution
0.1 °
Voltage supply
Power supply unit
24 V DC (+20 % / -30 %)
Supply acc. to IEC 742 with secure mains supply
isolation and equalization for voltage dips of up to
20 ms acc. to EN 61496-1.
Voltage supply
Battery
24 V DC (+20 % / -30 %)
(performance data may differ)
Overcurrent protection
Via 2 A semi-time-lag fuse in the cabinet
Notice: With high external loads at the switching
outputs (total current > 700 mA), the fuse rating
must be adjusted to 2.5 A.
Current consumption
Approx. 700 mA (use power supply unit with 3 A)
Power consumption
17 W with 24 V plus output capability
Overvoltage protection
Overvoltage protection with protected limit stop
Protective conductor
Connection required
Device connection
Connection cable, M12-8 connector
Connection socket for Ethernet/communication
M12-4 connector, D-coded