Menu description
Leuze electronic
BCL 608i
37
8
Menu description
After voltage is applied to the bar code reader, a startup screen is displayed for several seconds. The
display then shows the bar code reading window with all status information.
8.1
The main menus
Use the navigation buttons
to move through the menu. Activate the desired selection with the enter
button .
8.2
Parameter menu
Parameter handling
The Parameter handling submenu is used to lock and release the parameter input via the display and for
resetting to default values.
Table 8.1:
Parameter handling submenu
Decoder table
In the Decoder table submenu, 4 different code type definitions can be stored. Bar codes that have been
read can only be decoded if they correspond to one of the definitions stored here.
Device information
This menu item contains detailed information on
• Device type
• Software version
• Hardware version
• Serial number
Network settings
• Display of the network settings
Further information see chapter "Ethernet".
Bar code reading win
-
dow
• Visualization of the read bar code information
• Status overview of the switching inputs/outputs
• Bar graphs for read quality of the current bar code
Further information see chapter "Indicators in the display".
Parameter
• Configuration of the bar code reader
Further information see chapter 8.2 "Parameter menu".
Language selection
• Selection of the display language
Further information see chapter 8.3 "Language selection menu".
Service
• Scanner diagnosis and status messages
Further information see chapter 8.4 "Service menu".
Actions
• Various functions for scanner configuration and manual operation
Further information see chapter 8.5 "Actions menu".
The display offers only limited configuration options. The configurable parameters are described
in this chapter. Only the webConfig tool provides complete configuration options and is largely
self-explanatory. For the use of webConfig tool see chapter 9. Notes on commissioning via the
webConfig tool see chapter 10.
Level 3
Level 4
Level 5
Selection/configuration option
Description
Standard
Parameter enable
OFF/ON
The standard setting (OFF) prevents unintended parameter
changes.
If parameter enabling is activated (ON), parameters can be
changed manually.
OFF
Default parameters
By pressing the enter button after selecting
Parameters to default, all parameters are reset to their stan
-
dard settings without any further security prompts.
In this case, English is selected as the display language.