Device description
Leuze electronic
BCL 608i
15
3.5.2 Status display and operation
Indicators in the display
Table 3.1:
Status displays of the switching inputs/outputs
Table 3.2:
Status display of the USB interface
Read result
The read bar code information is displayed.
3.5.3 LED indicators
PWR LED
IO1
Switching input or switching output 1 active (function dependent on set configuration).
Default: Switching input with the “Reading gate activation” function
IO2
Switching input or switching output 2 active (function dependent on set configuration).
Default: Input with the “Teach-in” function
IO3
Switching input or switching output 3 active (function dependent on set configuration).
Default: Switching input with the “Reading gate activation” function
IO4
Switching input or switching output 4 active (function dependent on set configuration).
Default: Switching output with the “No read” function
ATT
Warning (Attention)
ERR
Internal device error (Error) -> The device must be sent in for inspection
USB
The device is connected to a PC via the USB interface.
MS
An external parameter memory is properly connected to the USB interface of the device.
Off
Device OFF
• No supply voltage
Flashes green
Device ok, initialization phase
• No bar code reading possible
• Voltage connected
• Self test running
• Initialization running
Green, continu
-
ous light
Device OK
• Bar code reading possible
• Self test successfully finished
• Device monitoring active
Orange, continu
-
ous light
Service mode
• Bar code reading possible
• Configuration via the USB service interface
• Configuration via the display
• No data on the host interface
Flashes red
Device ok, warning set
• Bar code reading possible
• Temporary operating fault
Red, continuous
light
Device error / parameter enable
• No bar code reading possible