Online commands
Leuze electronic
BCL 608i
67
Parameter
PT<BCC type><PS type><Status><Addr.><P.value addr.>
<P.value addr+1>…[;<Addr.><P.value addr.>][<BCC>]
<BCC type>
Check-digit function during transmission,
unit [dimensionless]
0
No check digits
3
BCC mode 3
<PS type>
Memory from which the values are to be read,
unit [dimensionless]
0
Parameter values stored in the flash memory
3
Operating values stored in RAM
<Status>
Mode of parameter processing, no function here,
unit [dimensionless]
0
No reset after parameter change, no further parameters
1
No reset after parameter change, additional parameters follow
2
With reset after parameter change, no further parameters
6
Set parameters to factory setting, no further parameters
7
Set parameters to factory settings, lock all code types; the
code-type setting must follow in the command!
<Addr.>
Relative address of the data within the data set
aaaa Four-digit,
unit [dimensionless]
<P.value>
Parameter value of the -bb- parameter stored at this address.
The parameter set data is converted from HEX format to a 2-
byte-ASCII format for transfer.
<BCC>
Check sum calculated as specified under BCC type.
Command
PT