background image

Wireless CCD Scanner

- MS912 -

User's 

Manual

Version 1.

2

© 2014 unitech Electronics Co., Ltd. All rights reserved. unitech is a registered trademark of unitech Electronics Co., Ltd.

Summary of Contents for MS912

Page 1: ...Wireless CCD Scanner MS912 User s Manual Version 1 2 2014 unitech Electronics Co Ltd All rights reserved unitech is a registered trademark of unitech Electronics Co Ltd ...

Page 2: ......

Page 3: ...o a Host PC 3 Power Management 12 Charging the Battery 13 Chapter 3 Specification 15 Chapter 4 General Settings 17 Default Abort Check Version Setup Code Read 17 Reading Mode 17 Beep tone Terminator 19 Send Data Length Preamble Postamble 20 Accuracy Adjustment 21 Code ID Inverse Barcode 22 Symbologies Code Identifier 23 Set Code ID 24 Table of Contents ...

Page 4: ...ice ID 34 Set SPP Pincode 35 SPP Master Mode 36 SPP Remote Control Shut Down Disconnection 37 Batch Mode Binary Check Character 38 Memory Mode Enable Memory Delete Record 39 Memory Mode Data Output 40 Memory Mode Data Format Date Time Setup 42 Memory Mode Date Format Time Format 44 Memory Mode Quantity 46 Chapter 6 Symbologies 49 Enable Disable Barcode Symbology 49 China postcode Toshiba code 51 M...

Page 5: ...E 0 1 UPC E EXPAND 68 UPC A 69 EAN 8 70 EAN 13 ISSN ISBN ISMN 71 EAN UCC 128 Code 128 72 DataBar RSS Stacked Limited Expanded 73 Chapter 7 Symbologies 75 Full ASCII table Code 39 75 Function Key table Code 39 for PC AT 84 Trouble Shooting 87 Appendix I Default table 91 Appendix II Cable Pin Assignment 99 Appendix III Barcode test chart 101 Appendix IV Worldwide Support 103 ...

Page 6: ......

Page 7: ...ion The MS912 is the smallest wireless scanners in the market and is compatible with all major OS on the nowadays popular smartphones and tablet PCs via both HID and SPP profiles Enjoy the benefits of accelerated productivity lower cost of ownership and freedom of movement The MS912 is a multipurpose scanner from a partner you can trust Thank you for choosing Unitech products Application Warehouse...

Page 8: ...se contact your Unitech representative MS912 scanner Resource CD Quick Guide USB Charging Cable Hand Strap Quick Connection Card NOTE 1 The scanner s default power off idle mode time is 3 minutes 2 Please charge scanner for at least 2 hours prior to initial use 1 Mini USB port 4 Exit Window 2 Trigger 5 Hard Reset Button 3 LED Indicator ...

Page 9: ...man Interface Device HID Mode NOTE Android 2 x devices can work with MS912 in the SPP mode ONLY The SPP mode or and the HID mode are not definitely compatible with each version of Android OS and thus depends on the Android based hardware specifications defined by the Android device manufacturers Connecting via Human Interface Device HID Mode Recommended 1 Turn on the wireless device on your host P...

Page 10: ...lect this device on your host and begin to pair 8 Your Host device will ask you to type in a pin code a Use your host device keypad to enter this pin code b The pin code can be any set of numbers c We suggest using 4 numbers 9 Once you have entered the pin code on the Host device you need to set up the pin code on the MS912 to match a With the MS912 scan the Pincode Start barcode below Pincode Sta...

Page 11: ...e into your Host device a To do a test open up Word or Note Pad or even a new E mail anything that will allow you to type in data b Scan a number bar code from this manual c That number should appear on your Host device in the application you opened d If not please scan Disconnect barcode below and repeat steps 1 to 9 above NOTE To disconnect the scanner from the host or to switch the wireless pro...

Page 12: ...nd to activate the scanner 2 Scan DISCONNECT Disconnect 3 Scan BT mode HID non pincode the scanner will emit 8 beeps BT mode HID non pincode 4 Search for the scanner nearby around by using the Bluetooth module of your host PC 5 Click Add a device to search for a wireless scanner nearby around ...

Page 13: ...6 Click Wireless Scanner to add to the computer Then click Next 7 In this step the computer is connecting the wireless scanner When it connects click Next 8 Click Pair without using a code Then click Next ...

Page 14: ...river software is installed successfully 11 The scanner will beep twice to verify the connection NOTE In this mode the scanner is recognized by the host as a mouse pointing device If your host fails to find it please try Connecting via Human Interface Device HID Mode instead ...

Page 15: ...the SPP barcode below SPP 5 The scanner will emit several beeps 6 Conduct a search for the MS912 on your host Select Wireless Scanner from discovered device list and the scanner will beep twice 7 Enter pincode which is 1234 by default 8 Open serial communication software with a COM port see Device Manager properly set up 9 The scanner will beep twice and the indicator LED will turn off to verify t...

Page 16: ...ting Connected Android Samsung hTC Sony Simply follow instruction in BT mode HID page 30 in which step 5 6 can be skipped since Android devices will not require pincode for connection NOTE Touch Keyboard While connected with the scanner the Touch Keyboard on the Android smartphone or tablet might disappear To resolve this issue please change settings on Android device with below steps 1 Enter Sett...

Page 17: ...eric characters from Full ASCII Chart of Appendix A STEP 5 Scan a desired BT mode barcode SPP or HID to connect NOTE 1 If you have connected the scanner with the host BEFORE customizing your Bluetooth device name please remove the device and create a new connection to make sure device name is refreshed For PC it is recommended to restart the Bluetooth adaptor in order to refresh device name 2 At S...

Page 18: ...minute ranging from 10 seconds 00 10 to 60 minutes and 60 seconds 60 60 For example to set the timeout as 5 minutes 30 seconds 1 Scan Set Minute 2 Scan 0 5 on below numeric barcode table 3 Scan Set Minute 4 Scan Set Second 5 Scan 3 0 on below numeric barcode table 6 Scan Set Second No Timeout Scanner Always On DISABLE TIMEOUT B021 NUMERIC BARCODES 1 2 3 4 5 6 7 8 9 0 ...

Page 19: ... LED Beeper Indication Scanner Green LED Red LED Beeper Remark Power Off or Standby See Power Off Timeout Charging Solid Disconnected or Discoverable Flash Initializing Flash Flash 1 long beep Power Up 1 long beep Barcode scanning w o proper connection Flash 1 beep Successful barcode scan 1 Flash 1 beep Successful Connection 2 beeps Unsuccessful Pincode Setup Flash 3 short beeps Scan Pincode Stop ...

Page 20: ... 14 ...

Page 21: ...ustrial 2of 5 Codabar Matrix 2 of 5 Code 11 Code93 Code 32 Code 128 Standard Code 39 Full ASCII Code 39 Interleaved 2 of 5 ChinaPostal Code MSI Plessy Code UK PlessyCode EAN UCC 128 Telepen Code IATACode GS1 Databar Configuration Method Configuration barcodes Electrical Operation Voltage 3 7VDC 5 Battery Type Lithium Ion Current Consumption Operation mode 150mA Standby mode 65mA Battery Duration 5...

Page 22: ... supported Mini USB Interface Profile SPP HID Wireless Class Wireless Class 2 Mechanical Housing Material ABS Dimensions L65 x W24 x H18mm 2 6 x 0 9 x 0 7in Weight 24 6g 0 9oz Regulation Approvals FCC Class B CE Accessories Mini USB cable Hand Strap Tools CD ...

Page 23: ...DE READ B015 B016 Caution Scanning SETUP CODE OFF will turn the scanner into unprogrammable state and the scanner will not react to any configuration barcode Reading Mode F005 LED is always on The trigger does not function in Continuous Mode F001 The LED is on steady if a bar code is close to the scanner but starts flashing if no bar code is detected after 60 seconds The trigger does not function ...

Page 24: ...n when the trigger is pressed The LED will go off if no bar code has been detected after 60 seconds F003 The LED is always on when the trigger is pressed The LED will go off if one bar code is read NOTE 1 To extend the scanner s life keep the scanner set to Trigger Mode or Continuous Auto Off Mode 7KH LQGLFDWRU ZLOO JORZ IRU 22 5 ...

Page 25: ... with Preamble Postamble Barcode Length and Symbology ID disabled the scanner data output will be Barcode Data Terminator 1 For the Keyboard Wedge interface the default terminator is CR 2 For the USB interface the default terminator is CR 3 For the RS232 interface the default terminator is CR LF TERMINATOR D010 D011 D012 D013 D014 D015 D016 2 7KHz Buzzer F018 F020 F022 F0 F021 F01 ...

Page 26: ... STEP 3 Scan twice from FULL ASCII Table STEP 4 Scan PREAMBLE STEP 5 Scan POSTAMBLE STEP 6 Scan twice from FULL ASCII Table STEP 7 Scan POSTAMBLE DATA FORMAT Preamble Symbology ID Barcode Length Barcode Data Postamble Terminator NOTE 1 A PREAMBLE is a string of up to 16 characters added to the beginning of a scanned barcode 2 A POSTAMBLE is a string of up to 16 characters added to the end of a sca...

Page 27: ...bjects the decoded output a higher standard of accuracy The higher the number the greater the accuracy SETTING PROCEDURE 1 Scan ACCURACY ADJUSTMENT 2 Scan one digit 1 9 from barcode menu above 3 Scan ACCURACY ADJUSTMENT P023 RESET NOTE 1 The scanner will beep three times as reminder that a setting is not yet complete 2 If you make a mistake forget a step etc scan RESET to start again ...

Page 28: ...15 NOTE 1 Only ONE code ID will be sent 2 The code ID is located at the position before the bar code data and after the preamble EXAMPLE 1 Preamble 145287 2 Code ID enable AIM ID 3 Bar code symbologies EAN 13 5 145287 Preamble 145287 E0 CODE ID AIM ID E0 BARCODE DATA EAN 13 5 OUTPUT 145287 E0456398712345312411 ...

Page 29: ...nterleaved 2 of 5 CDV send CD Interleaved 2 of 5 CDV not send CD Interleaved 2 of 5 disable CDV I I1 H0 I3 H1 I0 H3 Databar Databar Stacked Databar Stacked Omnidirectional Databar Truncated G e0 Telepen ASCII Telepen Numeric U B0 B1 IATA 2 of 5 R R0 Industrial 2 of 5 V S0 Databar Limited C China Post Code H X0 Databar Expanded Q PDF417 Z E0 Databar Expanded Stacked SET ID SETTING PROCEDURES Steps ...

Page 30: ...AN 8 Set ID P002 Code 128 Set ID P010 UPC E Set ID P003 EAN 128 Set ID P016 UPC A Set ID P004 Telepen Set ID P022 Code 39 Set ID P005 Code 11 Set ID P009 Code 93 Set ID P013 Code 32 Set ID P011 Codabar Set ID P007 China Post Code TOSHIBA Code Set ID P012 ...

Page 31: ...e forget a step etc scan RESET to start again MSI Code Set ID P014 Full ASCII Code39 Set ID P008 UK Plessey Set ID P015 GS1 Databar RSS Limited Set ID P019 Matrix 2 of 5 Set ID P017 GS1 Databar RSS Expanded Set ID P020 Interleaved 2 of 5Set ID P006 GS1 Databar RSS Set ID P024 Industrial 2 of 5 Set ID P018 LABEL Code Set ID Reserved P020 ...

Page 32: ... 26 Inter block and Inter character Delay INTERBLOCK DELAY INTERCHARACTER DELAY 0mS B001 140uS B010 10mS B002 500uS B011 50mS B003 1mS B012 100mS B004 4mS B013 200mS B005 16mS B014 500mS B006 ...

Page 33: ... 27 Keyboard Layout KEYBOARD LAYOUT C010 C021 C026 C018 C024 C031 C012 C016 C030 C011 C023 C028 C014 C009 C027 C013 C025 C032 C017 C034 C033 C022 C029 C015 ...

Page 34: ...er is set to Caplock Free mode no matter keyboard Capslock LED indicator is ON or OFF output will be always the same as the Original barcode In other words what you see is what output is CODABAR is the exception 2 If ABCD ABCD abcd abcd ABCD T E abcd tn e are on they work independently according to their rules ...

Page 35: ...e before scanning above barcode USB VCP C006 Please connect the scanner with the host with mini USB cable and make sure the virtual com driver available on CD or from local distributor is properly installed before scanning above barcode Function Support Matrix Interface Profile Batch Mode Memory Mode Ez Utility Wireless BT HID BT SPP USB HID N A USB VCP N A NOTE For Ez Utility PC based software ut...

Page 36: ...Scan DISCONNECT 3 Scan BT mode HID non pincode the scanner will emit several beeps 4 Select Wireless Scanner from the discovered device list 5 For PC please click Pair without using a code 6 The scanner will beep twice to verify the connection Note In this mode the scanner emulates a mouse pointing device If your host fails to find it please try BT mode HID instead 1 second to activate the scanner...

Page 37: ...STEP 1 Pincode Start E032 STEP 2 Scan numeric barcodes see NUMERIC BARCODES below based on the pincode generated by the Bluetooth application NUMERIC BARCODES 1 6 2 7 3 8 4 9 5 0 STEP 3 Enter TX STEP 4 Pincode Stop E033 ...

Page 38: ...ch Keyboard Getting Connected Android Samsung hTC Sony Simply follow instruction in BT mode HID page 30 in which step 5 6 can be skipped since Android devices will not require pincode for connection NOTE Touch Keyboard While connected with the scanner the Touch Keyboard on the Android smartphone or tablet might disappear To resolve this issue please change settings on Android device with below ste...

Page 39: ... minute ranging from 10 seconds 00 10 to 60 minutes and 60 seconds 60 60 For example to set the timeout as 5 minutes 30 seconds 1 Scan Set Minute 2 Scan 0 5 on below numeric barcode table 3 Scan Set Minute 4 Scan Set Second 5 Scan 3 0 on below numeric barcode table 6 Scan Set Second No Timeout Scanner Always On DISABLE TIMEOUT B021 NUMERIC BARCODES 1 2 3 4 5 6 7 8 9 0 ...

Page 40: ...OOTH PROFILE page 30 to complete the configuration NOTE 1 If you have connected the scanner with the host BEFORE customizing your Bluetooth device name please remove the device and create a new connection to make sure device name is refreshed For PC it is recommended to restart the Bluetooth adaptor in order to refresh device name 2 At Step 3 the scanner will beep three times as an alert that more...

Page 41: ...this pincode with below steps STEP 1 Set SPP Pincode B024 STEP 2 Scan numeric barcodes see NUMERIC BARCODES below Up to 8 numbers can be set as SPP pincode NUMERIC BARCODES 1 6 2 7 3 8 4 9 5 0 STEP 3 Set SPP Pincode B024 STEP 4 Scan a desired BT mode in BLUETOOTH PROFILE P32 to complete the configuration ...

Page 42: ... methods 1 The barcode must be Code 39 with no checksum 2 Barcode data format LTB Target MAC address For example the target SPP slave device s MAC address is 001583522C3B Please encode LTB001583522C3B in Code39 barcode Then follow below steps to create connection STEP 1 SPP Master E042 STEP 2 LTB001583522C3B ...

Page 43: ...Host sends CR LF A L CR LF 8 bytes Scanner replys O K CR LF 4 bytes Beeper Response Host sends CR LF M 1 CR LF 8 bytes Scanner replys a short beep SHUT DOWN This configuration barcode will shut down the scanner immediately but still reserve the pairing record SHUT DOWN E255 DISCONNECTION DISCONNECT CLEAR PAIRING RECORD DISCONNECT KEEP PAIRING RECORD E031 E046 ...

Page 44: ...ARACTER ENABLE DISABLE E029 E030 Once enabled a checksum will be added to the end of each data to conduct Xor calculation For Bluetooth SPP USB VCP the BCC is 1 byte For Bluetooth HID the BCC are 2 bytes Example The barcode data is TEST with terminator CR LF 1 Bluetooth SPP USB VCP Data Format T E S T CR LF BCC BCC 54h 45h 53h 54h 0Dh 0Ah 11h 2 Bluetooth HID Data Format T E S T Enter BCC BCC 54h 4...

Page 45: ...r memory version only ENABLE MEMORY DISABLE MEMORY R001 R002 Once enabled the scanner will stop sending data via Bluetooth and start storing data into the internal flash disk 2MB Delete Last Record Clear All Record DELETE LAST RECORD CLEAR ALL RECORD R005 R004 ...

Page 46: ...a WIRELESS please do the following 1 Scan WIRELESS 2 Follow the steps on page 30 to connect to host via HID or SPP 3 Scan ENABLE MEMORY page 39 and scan your desired barcodes 4 To output data 1 OUTPUT DATA 2 OUTPUT DATA or send below string to the scanner CR LF O 1 CR LF Totals 8 bytes w o commas to further clear all stored data please send below string CR LF O 2 CR LF Totals 8 bytes w o commas ...

Page 47: ...lable on CD 2 Connect the scanner and the host with mini USB cable 3 Scan USB VCP 4 Scan ENABLE MEMORY page 39 and scan your desired barcodes 5 Establish communication by Windows HyperTerminal or other serial communication softwares 6 To output data 1 simply scan OUTPUT DATA 2 send below string to the scanner O 1 Totals 4 bytes w o commas 7 To further clear all stored data please send below string...

Page 48: ...Data 2 Date 5 Quantity 3 Time Example To change Data Format to Barcode Data Quantity Date Time 1 Scan Data Format 2 Scan 4 5 2 3 from page 83 3 Scan Data Format FIELD SEPARATOR R010 Default is comma You may replace it with any alphanumeric characters from the full ASCII table in User s Manual on CD Example To change Field Separator to Semicolon 1 Scan Field Separator 2 Scan from the full ASCII tab...

Page 49: ...1 from page 83 3 Scan Set Date SET TIME R007 Example To set Time to 08 10 30 am Hr Min Sec 1 Scan Set Time 2 Scan 0 8 1 0 3 0 from page 83 3 Scan Set Time To avoid Time and Date being reset to factory default due to running out of battery please fully charge the scanner for at least 3 hours before use Memory Mode Data Format Date Time Setup ...

Page 50: ... available formats and their setup codes Code Item Code Item 01 DD MM YYYY 09 DD MM YYYY 02 MM DD YYYY 10 MM DD YYYY 03 DD MM YY 11 DD MM YY 04 MM DD YY 12 MM DD YY 05 YYYY MM DD 13 YYYY MM DD 06 YY MM DD 14 YY MM DD 07 DD MM 15 DD MM 08 MM DD 16 MM DD Example To set Date Format to MM DD YY Code 12 1 Scan Date Format 2 Scan 1 2 from page 83 3 Scan Date Format ...

Page 51: ...ult Time Format is HH MM SS Code 01 below are available formats and their setup codes Code Item Code Item 01 HH MM SS 02 HH MM Example To set Time Format to HH MM Code 02 1 Scan Time Format 2 Scan 0 2 from page 83 3 Scan TimeFormat Memory Mode Date Format Time Format ...

Page 52: ...ta format is Barcode Data Quantity 3 Scan a random barcode it will be stored as Barcode Data 4 Scan SET QUANTITY 5 Scan the numeric barcodes in page 83 as desired ranges from 1 to 99999 it will be stored as Quantity 6 Scan SAVE DATA 7 Repeat Step 3 6 to complete your task 8 Output memory data refer to Data Output section in page 40 41 and the result will be Barcode Data 1 Quantity 1 Barcode Data 2...

Page 53: ...mple your data format is Barcode Data Quantity 3 Scan a random barcode it will be stored as Barcode Data 4 Repeat Step 3 to complete your task 5 Output memory data refer to Data Output section in page 40 41 and the result will be Barcode Data 1 00001 Barcode Data 2 00001 Barcode Data 3 00001 By default Quantity 00001 To remove Quantity from the data format simply repeat Step 2 but set Barcode Data...

Page 54: ... 48 ...

Page 55: ... 49 SYMBOLOGIES Chapter 6 Enable Disable Barcode Symbology ENABLE DISABLE A002 A003 K010 K011 K001 K002 L010 L011 N001 N002 M010 M011 J001 J002 J010 J011 I 001 I 002 L014 L015 ...

Page 56: ... 50 Enable Disable Barcode Symbology ENABLE DISABLE H001 H002 H007 H008 H019 H020 H013 H014 L001 L002 G008 G009 I 010 I 011 G010 G011 M001 M002 N017 N018 ...

Page 57: ... 51 China postcode Toshiba code Enable Disable Barcode Symbology ENABLE DISABLE N032 N033 N038 N039 N010 N011 N026 N027 N028 N029 G021 G022 K001 K004 K002 K005 K003 K006 K007 ...

Page 58: ...l only read bar codes that fall into those length parameters Bar codes shorter or longer than specified will not be read The default lengths for these are indicated in parentheses under the Min and Max bar codes for each symbology P023 RESET NOTE 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a step etc Scan RESET to start again ...

Page 59: ... 53 MSI code UK Plessey code MSI UK PLESSEY CODE L001 L010 L002 L011 L004 L012 L003 L013 L007 L008 L009 L005 L006 ...

Page 60: ...des that fall intothose length parameters Bar codes shorter or longer thanspecified will not be read The default lengths for these areindicated in parentheses under the Min and Max bar codesfor each symbology P023 RESET NOTE 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a step etc Scan RESET to start again APPENDIX FULL ASCII Co...

Page 61: ... 55 Code 93 Telepen IATA CODE 93 TELEPEN IATA G010 L014 N017 G011 L015 N018 G012 L020 N019 G013 L021 N020 N021 N022 N023 ...

Page 62: ...des that fall intothose length parameters Bar codes shorter or longer thanspecified will not be read The default lengths for these areindicated in parentheses under the Min and Max bar codesfor each symbology P023 RESET NOTE 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a step etc Scan RESET to start again APPENDIX FULL ASCII Co...

Page 63: ... 57 Interleaved 2 of 5 Code 11 INTERLEAVED 2 OF 5 CODE 11 J001 I 010 J002 I 011 J003 I 012 J004 I 013 J005 I 042 J008 I 043 J009 I 014 J014 I 015 J006 I 016 J007 ...

Page 64: ...des that fall intothose length parameters Bar codes shorter or longer thanspecified will not be read The default lengths for these areindicated in parentheses under the Min and Max bar codesfor each symbology P023 RESET NOTE 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a step etc Scan RESET to start again APPENDIX FULL ASCII Co...

Page 65: ... 59 Industrial 2 of 5 Matrix 2 of 5 INDUSTRIAL 2 OF 5 MATRIX 2 OF 5 N001 M010 N002 M011 N003 M012 N004 M013 N005 M014 N006 M015 N007 M016 ...

Page 66: ...des that fall intothose length parameters Bar codes shorter or longer thanspecified will not be read The default lengths for these areindicated in parentheses under the Min and Max bar codesfor each symbology P023 RESET NOTE 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a step etc Scan RESET to start again APPENDIX FULL ASCII Co...

Page 67: ...I 004 I 009 Example of ST Start SP Stop 123456 Not Transmit ST SP A123456B ST SP ABCD ABCD a123456b ST SP abcd abcd A123456N ST SP ABCD TN E a123456n ST SP abcd tn e CLSI Enable library space insertion If you enable the CLSI format this option inserts spaces in position 2 7 13 of the data string for use in library systems ...

Page 68: ...des that fall intothose length parameters Bar codes shorter or longer thanspecified will not be read The default lengths for these areindicated in parentheses under the Min and Max bar codesfor each symbology P023 RESET NOTE 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a step etc Scan RESET to start again APPENDIX FULL ASCII Co...

Page 69: ...is a variant of the CODABAR Code developed for the use in the blood bank This Code consists of two bar codes which are decoded in one read cycle The code is concatenated when the stop character of the first bar code and the start character of the second bar code is a D these two D are not transmitted REMARK The CX Code consists of two bar codes which are decoded in one read cycle the code is conca...

Page 70: ...ake a mistake forget a step etc scan RESET to start again CODABAR COUPLING I 019 I 020 I 021 I 041 I 026 ABC Codabar and CX Codabar have certain rules regarding the Stop Character of first bar code and the stop character of second bar code while in conjunction while Codabar Coupling is enabled the data from any two Codabar bar codes can be coupled into one set of data without any limitations betwe...

Page 71: ...RD CODE 39 FULL ASCII 39 G008 G009 G001 G002 G014 G003 G004 G005 G006 G007 G015 NOTE The default for Code 39 is Standard Code 39 If Full ASCII Code 39 is enabled Standard Code 39 will be automatically disabled CODE 32 K010 K011 K012 K013 K014 K015 ...

Page 72: ...des that fall intothose length parameters Bar codes shorter or longer thanspecified will not be read The default lengths for these areindicated in parentheses under the Min and Max bar codesfor each symbology P023 RESET NOTE 1 The scanner will beep three times as a reminder that a setting is not yet complete 2 If you make a mistake forget a step etc Scan RESET to start again APPENDIX FULL ASCII Co...

Page 73: ...048 H056 H055 NOTE If ADDENDA REQUIRED is set to ON the scanner will only read an UPC E bar code that has an addenda At the same time please also scan 5 ON or 2 ON so the scanner will output a 5 digit or 2 digit addendum UPC E H007 H008 H009 H010 H011 H012 ...

Page 74: ...e UPC E 0 selection For the bar codes that lead with the 1 number use UPC E 1 selection UPC E EXPAND TO UPC A H053 H054 NOTE 1 If UPC E EXPAND TO UPC A FORMAT is enabled the output of UPC A will be 12 digits 2 The default output of UPC A is 12 digits if UPC A EXPAND TO EAN13 is enabled a zero will be added to in front of the bar code ...

Page 75: ...034 H035 H036 H045 H046 H060 H059 NOTE If ADDENDA REQUIRED is set to ON the scanner will only read an UPC E bar code that has an addenda At the same time please also scan 5 ON or 2 ON so the scanner will output a 5 digit or 2 digit addendum UPC A EXPANDTO EAN 13 H068 H067 ...

Page 76: ...SUPPLEMENT H029 H030 H031 H032 H043 H044 H062 H061 NOTE If ADDENDA REQUIRED is set to ON the scannerwill only read an UPC E bar code that has an addenda At the same time please also scan 5 ON or 2 ON sothe scanner will output a 5 digit or 2 digit addendum ...

Page 77: ... will be considered as an extension of EAN 13 If ISSN or ISBN needs to be read EAN 13 must be enabled If ISSN and ISBN need to be read with addenda EAN 13 must be enabled with ADDENDA REQUIRED set to ON and 2 ON or 5 ON must be enabled as well ISSN H052 H051 NOTE Both ISSN and ISBN are the extension codes of EAN 13 If scanner is required to read either ISSN or ISBN EAN 13 must be enabled Otherwise...

Page 78: ...07 NOTE DEFINE EAN 128 IThe first FNC1 character is translated to c1 and the second FNC1 character is translated to an ASCII GS character scan from page 75 86 String format C1 DATA CHARACTERS GS DATA CHARACTERS Setting Procedure 1 Scan DEFINE EAN128 2 Scan ASCII Code page 75 86 3 Scan DEFINE EAN128 ...

Page 79: ...Stacked Limited Expanded GS1 DataBar RSS OMNI STACKED N032 N034 N036 N038 P024 N033 N035 N037 N039 GS1 DataBar RSS LIMITED N010 N012 N024 P019 N011 N013 N025 GS1 DataBar RSS EXPANDED N026 N028 N030 P020 N027 N029 N031 ...

Page 80: ... 74 ...

Page 81: ... 75 SYMBOLOGIES Chapter 7 Full ASCII table Code 39 CONTROL CODES NUL U BS H SOH A HT I STX B LF J ETX C VT K EOT D FF L ENQ E CR M ACK F SO N BEL G SI O ...

Page 82: ... 76 Full ASCII table Code 39 CONTROL CODES DLE P EM Y DC1 Q SUB Z DC2 R ESC A DC3 S FS B DC4 T GS C NAK U RS D SYN V US E ETB W SP CAN X ...

Page 83: ... 77 Full ASCII table Code 39 SYMBOLS C N S F J 0 L H A Q V ...

Page 84: ... 78 Full ASCII table Code 39 SYMBOLS P W R B K G M L H F I Z G J I DEL T ...

Page 85: ... 79 Full ASCII table Code 39 UPPER CASE ALPHABETS A A H H B B I I C C J J D D K K E E L L F F M M G G N N ...

Page 86: ... 80 Full ASCII table Code 39 UPPER CASE ALPHABETS O O U U P P V V Q Q W W R R X X S S Y Y T T Z Z ...

Page 87: ... 81 Full ASCII table Code 39 LOWER CASE ALPHABETS a A h H b B i I c C j J d D k K e E l L f F m M g G n N ...

Page 88: ... 82 Full ASCII table Code 39 LOWER CASE ALPHABETS o O u U p P v V q Q w W r R x X s S y Y t T z Z ...

Page 89: ... 83 Full ASCII table Code 39 NUMBERS 0 5 1 6 2 7 3 8 4 9 ...

Page 90: ... 84 FUNCTION KEYS F1 TA F9 TI F2 TB F10 TJ F3 TC F11 TK F4 TD F12 TL F5 TE Home TM F6 TF End TN F7 TG Enter Numeric Key T D F8 TH App T O Function Key table Code 39 for PC AT ...

Page 91: ... 85 NAVIGATION KEYS Cursor Right TO Back Tab TV Cursor Left TP Esc TW Cursor Up TQ Enter TX Cursor Down TR BS TY Page Up TS Ins TZ Page Down TT Del T K Tab TU 62 64 ...

Page 92: ...H For UK Keyboard Special Character T B T C NOTE 1 When Alt Left Make is programmed please scan Alt Left Break to resume barcode setting 2 When Shift Left Make is programmed please scan Shift Left Break to resume barcode setting 3 When Ctrl Left Make is programmed please scan Ctrl Left Break to resume barcode setting ...

Page 93: ...oblem with the scanning technique or the interface configuration setting Reset the scanner to default 3 If the scanner indicates a good read but there is no output of data to the monitor please check the cabling connection KEYBOARD INTERFACES PROBLEMS In general the Keyboard Wedge interface is trouble free but there is still something to check in the event of a problem Do you have the correct cabl...

Page 94: ...of PC terminal No power supply to the scanner 1 Do you connect the right power adaptor to the scanner 2 Does scanner connect the cable with right pinout which match to PC terminal INTERFACE PROBLEMS Are you using the Wand Emulation mode with Code 39 output If so is your decoder set to accept Code 39 data Check the scanner s conıguration setting to make sure it can accept the bar code symbology you...

Page 95: ...scanning of other symbologies Does the selected bar code symbology conı guration match the bar code s being read Scanned data from each bar code symbology can be restricted to eliminate the scanning of unused symbologies The restrictions are individually set for each symbology POOR BAR CODE QUALITY The third problem area has nothing to do with the scanner but rather the printed quality of the bar ...

Page 96: ...mbination of the label color and the color of the ink can in effect blind the scanner Media with a shiny surface will also cause reading difficulties for scanners Moreover poor printing quality can also result in reading difficulties for the scanner Bad printing may be caused by the type of printer used dot matrix and inkjet printers will not procedure high quality bar codes Also check to make sur...

Page 97: ... Code Interval Laser Scanner 30 Sec Idle Mode Off Pre Idle Time 1 Min 2 6 Connection Options BT HID 2 8 Wireless ID Wireless Scanner 2 9 Power Off Timeout 3 Min 2 10 SSP Secure Simple Pairing Disable iOS Hotkey Disable 2 11 Link Quality Disable Batch Mode Disable 2 13 SPP Pincode 1234 2 15 Memory Mode Disable Data Output Method Wireless 2 16 Data Format Item No Date Time Barcode Data Field Separat...

Page 98: ...Off Numeric Key Alphanumeric Key 12 Baud Rate 9600 Data Bits Parity 8 Bits None 13 Stop Bits 1 stop bit Handshaking None ACK NAK Off Flow Control Timeout 1 Sec BCC Off 14 Level duration of Mini Width 200us Polarity of Idle Condition High Output of Wand Emulation Bar High Space Low Wave Form Full ASCII 39 Idle Mode Off Pre Idle Time 1 Min 15 Enable and Disable Symbologies Code 32 Disable China Post...

Page 99: ...GS1 Databar Stacked Enable GS1 Databar Limited Disable GS1 Databar Expanded Disable GS1 Databar Expanded Stacked Enable PDF417 Disable 2 China Post Code Enable Disable Enable Check Digits Disable CDV Min Length 11 digits Max Length 48 digits 18 1 MSI Enable Disable Disable Check Digits CDV send CD Check Digits Mode 18 Single MOD 10 2 UK Plessy Enable Disable Disable Check Digits CDV not send CD ...

Page 100: ... 1 Interleaved 2 of 5 Enable Disable Enable Check Digits Disable CDV First last digit suppressed No suppressed Min Length 6 digits Max Length 48 digits 2 Code II Enable Disable Disable Check Digits Disable CDV Min Length 6 digits Max Length 32 digits 21 1 Industrial 2 of 5 Enable Disable Disable Check Digits Disable CDV Min Length 6 digits Max Length 48digits 2 Matrix 2 of 5 Enable Disable Disable...

Page 101: ... Start ST Stop SP Send CLSI Format On 23 1 ABC Codabar ON OFF Off Insert Data Off 2 CX Codabar ON OFF Off Insert Data Off 24 Codabar Coupling ON OFF Off Insert Data Off Adjacent Required Off 25 1 Code 39 Full ASCII 39 Enable Disable Enable Check Digits Disable CDV Start Stop Not Send Min Length 1 digit Max Length 48 digits 2 Code 32 Enable Disable Disable Leading send Tailing send ...

Page 102: ...ystems number UPC E 0 On Off On UPC E 1 On Off Off UPC E expand to UPC A Disable UPC A expand to EAN 13 Disable 28 UPC A Enable Disable Enable Check Digits Send Lead Digits Send Add a space Off Addenda required Off 5 On Off Off 2 On Off Off 29 EAN 8 Enable Disable Enable Check Digits Send Lead Digits Send Add a space Off Addenda required Off 5 On Off Off 2 On Off Off ...

Page 103: ... Func 1 Char Send Not Send 2 Code128 Enable Disable Enable Check Digits Disable CDV Min Length 5 digits Max Length 48 digits 3 PDF417 Enable Disable Disable 32 GS1 Databar Disable GS1 Databar Check Digit Not Send GS1 Databar Prefix Not Send GS1 Databar Stacked Enable GS1 Databar Limited Disable GS1 Databar Limited Check Digit Not Send GS1 Databar Limited Prefix Not Send GS1 Databar Expanded Disabl...

Page 104: ... 98 ...

Page 105: ... 2 Din 5 male 240 degree Pin Signal 1 5VCC 2 Data 3 GND 4 N A 5 N A 2 Keyboard Interface Din6 Female 2 1 PS 2 Mini Din6 Female Pin Signal 1 PC Data 2 NC 3 GND 4 5VCC 5 PC Clk 6 NC 2 2 PS 2 Mini Din6 Male Pin Signal 1 KB Data 2 NC 3 GND 4 5VCC 5 KB Clk 6 NC Cable Pin Assignment Appendix II ...

Page 106: ...B Clk 2 KB Data 3 NC 4 GND 5 5VCC 2 4 PC AT Din 5 Female Pin Signal 1 PC Clk 2 PC Data 3 NC 4 GND 5 5VCC 3 RS232 Interfaces 3 1 DB9F Pin Signal 2 TXD Out 3 RXD In 5 GND 7 CTS In 8 RTS Out 9 5VCC 3 2 DB25F Pin Signal 2 RXD In 3 TXD Out 4 CTS In 5 RTS Out 7 GND 16 5VCC 28 5VCC ...

Page 107: ... 101 DENSITY NARROW mm mil WIDE mm mil CHAR GAP mm mil N W RATIO MEDIUM DENSITY 0 25 10 0 625 25 0 25 10 1 2 5 NW 7 CODABAR CODE 39 Interleaved 2of5 UPC EAN MEDIUM DENSITY Barcode test chart Appendix II ...

Page 108: ... 102 DENSITY NARROW mm mil WIDE mm mil CHAR GAP mm mil N W RATIO MEDIUM DENSITY 0 25 10 0 625 25 0 25 10 1 2 5 LOW DENSITY ...

Page 109: ...ntative For complete contact information please visit the Web sites listed below Region Web Site Global Operation Center http www ute com Unitech Taiwan http tw ute com Unitech Asia Pacific Middle East http apac ute com http india ute com Greater China Division http cn ute com Unitech Japan http jp ute com Unitech North America http us ute com http can ute com Unitech Latin America http latin ute ...

Reviews: