Online commands
Leuze electronic
BCL 608i
57
Software reset
Code recognition
autoConfig
Command
H
Description
Carries out a software reset. The device is restarted and reinitialized, leaving
it in the same state as when the supply voltage is switched on
Parameter
No
Acknowledgment
S (start signal)
Command
CC
Description
Detects an unknown bar code and outputs number of digits, code type, and
code information to the interface, without storing the bar code in the parame
-
ter memory.
Parameter
No
Acknowledgment
xx yy zzzzzz
xx:
Number of digits of the read code
yy:
Code type of the read code
01
2/5 Interleaved
02
Code 39
06
UPC (A, E)
07
EAN
08
Code 128, EAN 128
10
EAN Addendum
11
Codabar
zzzzzz
Contents of the decoded label. A appears if the label was not
correctly read
Command
CA
Description
Activates or deactivates the autoConfig function. Certain label reading param
-
eters are programmed automatically in the setup by the labels which the
device reads while the autoConfig function is active.
Parameter
+
Activates autoConfig
/
Rejects the last code read
-
Deactivates autoConfig and stores the decoded data in the cur
-
rent parameter set