PROFIBUS interface
67
AMS 304
i
Leuze electronic
9.4.3.7
Module 6: Status and control
Description
The module supplies various AMS 304
i
status information to the PROFIBUS master. The
laser can be controlled via the master's output data.
Parameters
no
Input data
Input data
Description
Rel.
addr.
Data
type
Value
Default
Unit
CR to
module
metr.
Inch
Laser
status
Signals the laser status.
1.0
Bit
0: Laser ON
1: Laser OFF
–
–
–
Preset
status
Status of the preset value.
1.1
Bit
0: Preset not active
1: Preset active
–
–
–
Preset teach
This bit toggles on each teach event of a
preset value.
1.2
Bit
0 or 1
–
–
–
Overflow
The output value has exceeded the max-
imum value which can be represented by
the SSI interface. In the event of an over-
flow the SSI interface data are set to
0xFF.
1.3
Bit
0: OK
1: Overflow
–
–
–
Intensity
(ATT)
If the intensity of the received signal is
less than the warning threshold, the sta-
tus bit is set.
1.4
Bit
0: OK
1: Warning
–
–
–
Temperature
(TMP)
If the internal device temperature
exceeds or drops below the set limit
value, the status bit is set.
1.5
Bit
0: OK
1: Temperature above/below
limit
–
–
–
Laser (LSR)
Laser prefailure message.
1.6
Bit
0: OK
1: Laser warning
–
–
–
Plausibility
(PLB)
If implausible measurement values are
diagnosed, the status bit is set.
1.7
Bit
0: OK
1: Implausible measurement
value
–
–
–
Hardware
(ERR)
If a hardware error is diagnosed, the sta-
tus bit is set.
0.0
Bit
0: OK
1: Hardware error
–
–
–
Lower
position limit
value 1
Signals that the value is less than lower
limit value 1.
0.4
Bit
0: OK
1: Value less than limit
–
–
–
Upper
position limit
value 1
Signals that the value is greater than
upper limit value 1.
0.5
Bit
0: OK
1: Value greater than limit
–
–
–