PROFIBUS interface
55
AMS 304
i
Leuze electronic
Table 9.1:
Overview of the GSD modules
M11
Velocity
limit value 1
(P) Monitoring for over/under values
(P) Monitoring direction dependent yes/no
(P) Velocity limit value 1
(P) Hysteresis of velocity limit value
(P) Start of velocity monitoring range
(P) End of velocity monitoring range
M12
Velocity
limit value 2
(P) Monitoring for over/under values
(P) Monitoring direction dependent yes/no
(P) Velocity limit value 2
(P) Hysteresis of velocity limit value
(P) Start of velocity monitoring range
(P) End of velocity monitoring range
M13
Velocity
limit value 3
(P) Monitoring for over/under values
(P) Monitoring direction dependent yes/no
(P) Velocity limit value 3
(P) Hysteresis of velocity limit value
(P) Start of velocity monitoring range
(P) End of velocity monitoring range
M14
Velocity
limit value 4
(P) Monitoring for over/under values
(P) Monitoring direction dependent yes/no
(P) Velocity limit value 4
(P) Hysteresis of velocity limit value
(P) Start of velocity monitoring range
(P) End of velocity monitoring range
M15
Velocity
Limit value
Dynamic
(O) Release/lock limit value control
(P) Monitoring for over/under values
(P) Monitoring direction dependent yes/no
(O) Dynamic velocity limit value
(O) Hysteresis of velocity limit value
(O) Start of velocity monitoring range
(O) End of velocity monitoring range
M16
Velocity status
(I) Status of velocity monitoring
M17
SSI interface
(P) Gray/Binary coding
(P) Number of data bits
(P) Resolution
(P) Update rate
(P) Function of the error bit
M18
Other
(P) Display language selection
(P) Display illumination
(P) Display contrast
(P) Activate/inhibit password
(P) Password
(P) Heating control
M19
Free resolution
(P) Position resolution
(P) Velocity resolution