PROFIBUS interface
Leuze electronic
AMS 304
i
50
TNT
35/7-2
4
V
9
PROFIBUS interface
9.1
General information on PROFIBUS
The AMS 304
i
is designed as a PROFIBUS DP device for cyclical (V0) as well as acyclic (V1)
data exchange.
For this purpose the functionality of the laser is defined via GSD parameter sets. The max.
baud rate of the data to be transferred is 12 Mbit/s.
The PROFIBUS interface can be used parallel to the SSI interface. PROFIBUS and SSI
interfaces are activated by default.
Notice!
The PROFIBUS interface can be activated/deactivated via the display. To activate /
deactivate the interface, parameter enabling must be activated (see chapter 8.3.2
).
The
respectively active interface is shown in the display; when PROFIBUS is activated, the
address set is visible in the display.