11
8
COMMISSIONING MANUAL
POWERDRIVE MD
Variable speed drive
MENUS AND DIAGRAMS IN ADVANCED SET UP MODE
LEROY-SOMER
3871 en - 2011.05 / h
: PID hold inte
g
rator
Adjustment range : Disabled (0) or Enabled (1)
Factory setting
: Disabled (0)
Disabled (0): Inte
g
ration is carried out normally when the
PID loop is activated.
Enabled (1):
The value of the integrator is frozen and
remains at this value until
14.17
goes back to Disabled (0).
In both cases, when the PID controller has been disabled, the
integrator value is reset to Disabled (0).
: PID symmetrical limit enable
Adjustment range : Disabled (0) or Enabled (1)
Factory setting
: Disabled (0)
When
14.18
is set to Enabled (1),
14.13
and
14.14
take
the same value and
14.13
is the parameter that takes effect.
: PID main reference
Adjustment range : ± 100.0%
This parameter indicates the value of the main reference.
: PID reference
Adjustment range : ± 100.0%
This parameter indicates the value of the PID reference.
: PID feedback
Adjustment range : ± 100.0%
This parameter indicates the value of the PID feedback.
: PID error
Adjustment range : ± 100.0%
This parameter indicates the error between the main
reference and the feedback.
to
: Not used
: Buffer no. 1
Adjustment range : ± 100.00%
Factory setting
: 0%
This parameter is used to assign an analog input to the PID
reference or feedback.
: Buffer no. 2
Adjustment range :± 100.00%
Factory setting
: 0%
This parameter is used to assign an analog input to the PID
reference or feedback.
14.17
14.18
14.19
14.20
14.21
14.22
14.23
14.50
14.51
14.52