MENUS AND DIAGRAMS IN ADVANCED SET UP MODE
LEROY-SOMER
3871 en - 2011.05 / h
: Menu to be saved
Adjustment range : 0 to 21
Factory setting
: 0
This parameter is used to choose the menu(s) to be saved
(
11.65
= 0 for all menus)
: Communication type between drives
Adjustment range : NONE (0), Invert. REGEN (1),
Rectif. REGEN (2), MASTER TWIN (3),
SLAVE TWIN (4), MASTER Synch (5),
SLAVE Synchr (6)
Factory setting
: NONE (0)
0 : NONE
1:
Invert. REGEN
2:
Rectif. REGEN
3:
MASTER TWIN
4:
SLAVE TWIN
5:
MASTER Synch
6:
SLAVE Synchr
The modification is not taken into account until after the
drive has been powered down.
Note:
For versions < 03.00, communication types 2, 4 and 6
can be used only with a specific control board.