3-phase mains connection 480 V "Light Duty"
Rated data
The output currents apply to these operating conditions:
•
At switching frequency 2 kHz or 4 kHz: Ambient temperature max. 40 °C (104 °F).
Inverter
I51AP
175F
211F
215F
222F
230F
240F
255F
Rated power
P
rated
kW
1.1
1.5
2.2
3
4
5.5
7.5
Rated power
P
rated
HP
1.5
2
3
4
5
7.5
10
Mains voltage range
3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Output voltage
3 AC 0 - 400/480 V
Rated mains current
without mains choke
A
3.9
4.2
5.1
7.3
8.6
11.2
15.3
with mains choke
A
-
Apparent output power
kVA
2.4
2.8
3.9
5.1
6.6
8.9
11.3
Rated output current
2 kHz
A
2.5
3.6
4.2
5.8
7.6
9.8
13.2
4 kHz
A
2.5
3.6
4.2
5.8
7.6
9.8
13.2
Power loss
2 kHz
W
38
45
62
79
102
137
172
4 kHz
W
40
48
66
84
108
145
183
Cyclic mains switching
3 times per minute
Brake chopper
Max. output current
-
Min. Brake resistor
-
Max. shielded motor cable
length
without EMC category
m
30
50
Category C1 (2 kHz, 4 kHz,
8kHz)
m
-
Category C2 (2 kHz, 4 kHz, 8
kHz)
m
-
Category C3 (2 kHz, 4 kHz, 8
kHz)
m
-
Max. Unshielded motor cable
length
without EMC category
m
60
80
100
Technical data
3-phase mains connection 480 V "Light Duty"