Motor connection
Requirements for the shielded motor cable
Capacitance per unit
length
< 150/300 pF/m
C core-core/C core-shield ≤ 4 mm² / AWG 12
< 75/150 pF/m
C core-core/C core-shield ≤ 2.5 mm² / AWG 14
Electric strength
Uo/U = 0.6/1.0 kV
U = r.m.s. value from external conductor to external
conductor
Uo = r.m.s. value external conductor to PE
UL
U ≥ 600 V
U = r.m.s. value from external conductor to external
conductor
Environmental conditions
Energy efficiency
High Efficiency
EN 50598-2
Class IE2
Climate
Storage
EN 60721-3-1
1K3 (-30 ... +60 °C)
Transport
EN 60721-3-2
2K3 (-30 ...+70 °C)
Operation
EN 60721-3-3
3K3 (-30 ... +55 °C)
Operation at a switching frequency of 2 or 4 kHz: Above
+45°C: reduce rated output current by 2.5 %/°C
Operation at a switching frequency of 8, 12 or 16 kHz:
Above +40°C: reduce rated output current by 2.5 %/°C
Site altitude
0 … 1000 m ü. NN
1000 … 4000 m ü. NN
Reduce rated output current by 5 %/1000 m
Pollution
EN 61800-5-1
Degree of pollution 2
UL 61800-5-1
Vibration resistance
Transport
EN 60721-3-2
2M2 (sine, shock)
in original packaging
Operation
EN 61800-5-1
Amplitude 0.075 mm
10 ... 57 Hz
acceleration resistant up to 1
g
57 ... 150 Hz
German Lloyd
Amplitude 1 mm
5 ... 13.2 Hz
acceleration resistant up to
0.7 g
13.2 ... 100 Hz
Electrical supply conditions
Power systems
TN
Voltage to earth: max. 300 V
TT
Technical data
Standards and operating conditions
Electrical supply conditions
48
Содержание i510 protec
Страница 2: ......