1-phase mains connection 120 V
Rated data
The output currents apply to these operating conditions:
•
At switching frequency 2 kHz or 4 kHz: Ambient temperature max. 45 °C (113 °F).
•
At switching frequency 8 kHz, 12 kHz or 16 kHz: Ambient temperature max. 40 °C (104 °F).
Inverter
I51AP
137A
175A
Rated power
P
rated
kW
0.37
0.75
Rated power
P
rated
HP
0.5
1
Mains voltage range
1/PE AC 90 V ... 132 V, 45 Hz ... 65 Hz
Output voltage
3 AC 0 - 230/240 V
Rated mains current
without mains choke
A
9.6
16.8
with mains choke
A
-
Apparent output power
kVA
0.9
1.6
Rated output current
2 kHz
A
2.4
4.2
4 kHz
A
2.4
4.2
8 kHz
A
2.4
4.2
12 kHz
A
2.2
3.8
16 kHz
A
1.6
2.8
Power loss
2 kHz
W
19
30
4 kHz
W
20
32
8 kHz
W
24
40
12 kHz
W
23
38
16 kHz
W
22
35
Cyclic mains switching
3 times per minute
Brake chopper
Max. output current
-
Min. Brake resistor
-
Max. shielded motor cable
length
without EMC category
m
30
Category C1 (2 kHz, 4 kHz,
8kHz)
m
-
Category C2 (2 kHz, 4 kHz, 8
kHz)
m
-
Category C3 (2 kHz, 4 kHz, 8
kHz)
m
-
Max. Unshielded motor cable
length
without EMC category
m
60
Technical data
1-phase mains connection 120 V
Rated data
49
Содержание i510 protec