Diagnostics and fault elimination
Diagnostic interfaces
Depending on the purchase order, the inverter will include one of the following modules:
•
No module
•
Keypad
•
WLAN module
•
USB module
Further information on the diagnostic modules can be found here:
Keypad
WLAN module
A connection to the WLAN module is established using the connection data.
Connection data (default settings)
IP address
192.168.178.1
SSID
«Product type»_«10-character identification code»
Password
password
LED status display
"RDY" LED (blue)
"ERR" LED (red)
Status/meaning
Off
Off
Supply voltage not available.
On
On
Initialisation in progress (inverter is being started.)
Blinks (1 Hz)
Off
Safe torque off (STO) active. The inverter has been inhibited by the integrated safety
system.
Blinks (1 Hz)
On
Inverter inhibited, error active.
On
Off
Inverter enabled.
Motor rotates according to the specified setpoint or quick stop is active.
Both LEDs are blinking in a rapidly
alternating mode
Firmware update active.
Both LEDs are blinking in a very rapidly
synchronous mode
"Visual tracking" function is active.
Diagnostics and fault elimination
LED status display
46
Содержание i510 protec
Страница 2: ......