Keypad parameterisation mode
Function of the keypad keys in the parameterisation mode
In the parameterisation mode of the keypad you can have actual values of the inverter displayed for
purposes of diagnostics and change settings of the inverter.
Function of the keypad keys in the parameterisation mode
Key
Actuation
Condition
Action
Shortly
Local keypad control active.
Display "LOC"
Run motor.
Remote control active
Display "REM"
Display "KSTOP"
Deactivate keypad triggered stop.
The motor remains at standstill.
Display changes from "KSTOP" to "STOP".
Shortly
No Jog operation
Stop motor.
Display "KSTOP"
Shortly
Parameterisation mode
Navigate to one level below.
Group level
à
Parameter level
à
[SUB parameter level]
à
Editing mode
Editing mode
Exit editing mode and accept new setting.
Longer than 3 s None (anytime possible)
Save parameter settings in the user memory of the
memory module.
Shortly
Parameterisation mode
Navigate to one level above.
[SUB parameter level]
à
Parameter level
à
Group level
à
Operating mode
Editing mode
Abort: Exit editing mode without accepting new setting.
Shortly
Group level/Parameter level
Navigate: Select group/parameter.
Editing mode
Change parameter setting.
CTRL
Without function
R F
Without function
Using accessories
Keypad
Keypad parameterisation mode
45