3-phase mains connection 230/240 V
Rated data
The output currents apply to these operating conditions:
•
At switching frequency 2 kHz or 4 kHz: Ambient temperature max. 45 °C (113 °F).
•
At switching frequency 8 kHz, 12 kHz or 16 kHz: Ambient temperature max. 40 °C (104 °F).
Inverter
I51AP
137D
175D
211D
215D
222D
230C
240C
Rated power
P
rated
kW
0.37
0.75
1.1
1.5
2.2
3
4
Rated power
P
rated
HP
0.5
1
1.5
2
3
4
5
Mains voltage range
3/PE AC 195 V ... 264 V, 45 Hz ... 65 Hz
Output voltage
3 AC 0 - 230/240 V
Rated mains current
without mains choke
A
3.9
6.4
7.8
9.5
13.6
15
20.6
with mains choke
A
-
Apparent output power
kVA
0.9
1.6
2.3
2.6
3.6
4.5
6.2
Rated output current
2 kHz
A
2.4
4.2
6
7
9.6
12
16.5
4 kHz
A
2.4
4.2
6
7
9.6
12
16.5
8 kHz
A
2.4
4.2
6
7
9.6
12
16.5
12 kHz
A
2.2
3.8
5.4
6.3
8.6
10.8
14.9
16 kHz
A
1.6
2.8
4
4.7
6.4
8
11
Power loss
2 kHz
W
19
30
38
45
62
79
102
4 kHz
W
20
32
40
48
66
84
108
8 kHz
W
24
40
51
61
85
109
140
12 kHz
W
23
38
54
65
91
104
133
16 kHz
W
22
35
49
58
81
104
133
Cyclic mains switching
3 times per minute
Brake chopper
Max. output current
-
Min. Brake resistor
-
Max. shielded motor cable
length
without EMC category
m
30
50
Category C1 (2 kHz, 4 kHz,
8kHz)
m
-
Category C2 (2 kHz, 4 kHz, 8
kHz)
m
-
Category C3 (2 kHz, 4 kHz, 8
kHz)
m
-
Max. Unshielded motor cable
length
without EMC category
m
60
80
100
Technical data
3-phase mains connection 230/240 V
Rated data
52
Содержание i510 protec
Страница 2: ......