1-phase mains connection 230/240 V "Light Duty"
Rated data
The output currents apply to these operating conditions:
•
At switching frequency 2 kHz or 4 kHz: Ambient temperature max. 40 °C (104 °F).
Inverter
I51AP
137D
175D
211D
215D
222D
Rated power
P
rated
kW
0.55
1.1
1.5
2.2
3
Rated power
P
rated
HP
0.75
1.5
2
3
4
Mains voltage range
1/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Output voltage
3 AC 0 - 230/240 V
Rated mains current
without mains choke
A
6.9
12
17.1
20
27.4
with mains choke
A
-
Apparent output power
kVA
1.2
2.2
2.6
3.6
4.9
Rated output current
2 kHz
A
2.9
5
7.2
8.4
11.5
4 kHz
A
2.9
5
7.2
8.4
11.5
Power loss
2 kHz
W
30
38
45
62
79
4 kHz
W
32
40
48
66
84
Cyclic mains switching
3 times per minute
Brake chopper
Max. output current
-
Min. Brake resistor
-
Max. shielded motor cable
length
without EMC category
m
30
Category C1 (2 kHz, 4 kHz,
8kHz)
m
-
Category C2 (2 kHz, 4 kHz, 8
kHz)
m
-
Category C3 (2 kHz, 4 kHz, 8
kHz)
m
-
Max. Unshielded motor cable
length
without EMC category
m
60
80
Technical data