Communication manual 8400 motec PROFIBUS
Parameter reference
Parameters relevant for PROFIBUS communication
C13853
C13860
C13861
Parameter | Name:
C13853 | All words from standard device
Data type: UNSIGNED_16
Index: 10722
d
= 29E2
h
Display of the process data words 1 ... 8 transferred from the drive unit to the communication unit.
In the subcodes 1 ... 8, all process data words of the drive unit are displayed.
Display area
(min. value | unit | max. value)
0
65535
Subcodes
Info
C13853/1
Word 1 from drive unit
...
...
C13853/8
Word 8 from drive unit
;
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13860 | Settings
Data type: UNSIGNED_8
Index: 10715
d
= 29DB
h
Display of the current configuration data.
Display area
(min. value | unit | max. value)
0
255
Subcodes
Info
C13860/1
Reserved
C13860/2
Number of process data words
• 1 ... 8 words
C13860/3
DRIVECOM parameter data channel
• 0: Not active
• 1: Active
C13860/4
Reserved
;
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13861 | Bus status
Data type: UNSIGNED_16
Index: 10714
d
= 29DA
h
Bit-coded display of the current bus state.
Querying the current bus status (
Display area
(min. value | unit | max. value)
0
65535
;
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT