![Lenze E84DGFCp Series Скачать руководство пользователя страница 66](http://html.mh-extra.com/html/lenze/e84dgfcp-series/e84dgfcp-series_communications-manual_1882011066.webp)
Communication manual 8400 motec PROFIBUS
Parameter data transfer
PROFIdrive parameter data channel (DP-V1)
66
L
EDS84DMOTPBUS EN 3.0 - 11/2011
Parameter response to a correctly executed read request
Parameter response to a read error
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identification
Axis
Number of indices
0xXX
0x01
0x00
0x01
(mirrored)
Parameter has been read
(mirrored)
Byte 5
Byte 6
Format
Number of values
0x03
0x01
Integer16
1 value
Byte 7
Byte 8
Value
High byte
Low byte
0x00
0x2B
Value read = 0x 00 2B = 43 x 1 (internal factor) = 43 [°C]
Byte 1
Byte 2
Byte 3
Byte 4
Request reference
Response identification
Axis
Number of indices
0xXX
0x81
0x00
0x01
(mirrored)
Parameter has not been read
(mirrored)
Byte 5
Byte 6
Format
Number of values
0x44
0x01
Error
Error code without additional
information
Byte 7
Byte 8
Error code
High byte
Low byte
For the meaning, see the "