EDS84DMOTPBUS EN 3.0 - 11/2011
L
91
Communication manual 8400 motec PROFIBUS
Parameter reference
Implemented PROFIdrive objects (DP-V1)
13.4
Implemented PROFIdrive objects (DP-V1)
I-918
I-963
I-964
Index | Name:
0x918 | Display of station address
Data type: U16
Display of the set station address (see also
Display area
(min. value | unit | max. value)
1
126
;
Read access
Write access
Index | Name:
0x963 | Baud rate
Data type: U16
Display of the PROFIBUS baud rate (see also
)
Selection list
(read only)
0 9.6 kbps
1 19.2 kbps
2 93.75 kbps
3 187.5 kbps
4 500 kbps
6 1.5 Mbps
7 3 Mbps
8 6 Mbps
9 12 Mbps
;
Read access
Write access
Index | Name:
0x964 | Device identification
Data type: U16
Display of identification data
Subindex
Display
Info
0x964/0
262
Manufacturer: Lenze
0x964/1
8400
Device type
0x964/2
xxyy
Software version, e.g. 0100 (V 01.00)
0x964/3
yyyy
Firmware date (year), e.g. 2007
0x964/4
ddmm
Firmware date (day/month), e.g. 0506 (5th June)
;
Read access
Write access