S94P01C -e1
69
P and D gains setting check (problem).
Position P-gain = 12673
Position D-gain = 16000
Position I-gain =
0
Position I-limit =
0
Problem:
Noticeable oscillation (Channel 1) on Iq current waveform.
Treatment:
Decrease the P-gain setting until oscillation disappears.
S945
P and D gains setting check (corrected)
Position P-gain = 12673
Position D-gain = 16000
Position I-gain =
0
Position I-limit =
0
Positive effect:
Oscillation stopped and stability is increased