S94P01C -e1
23
When using the E94ZARSV2, the default resolution is 1024 PPR prequadrature.
Depending on the Hardware/Software revision of the E94ZARSV2 module, the
available PPRs are different. Refer to the table below for the Dip Switch settings for
SW1 and the different resolutions.
SW1 DIP Switch Settings
Dip Switch SW1
PPR prequadrature
1)
Position 1 Position 2 Position 3 Position 4
Hardware/Software
Revision
2)
1A10,
1A11, 1B11, 1C11
Hardware/Software
Revision
2)
1C12
and higher
OFF
OFF
OFF
OFF
250
1024 (default)
OFF
OFF
OFF
ON
256
256
OFF
OFF
ON
OFF
360
360
OFF
OFF
ON
ON
400
400
OFF
ON
OFF
OFF
500
500
OFF
ON
OFF
ON
512
512
OFF
ON
ON
OFF
720
720
OFF
ON
ON
ON
800
800
ON
OFF
OFF
OFF
1000
1000
ON
OFF
OFF
ON
1024 (default)
1024 (default)
ON
OFF
ON
OFF
2000
2000
ON
OFF
ON
ON
2048
2048
ON
ON
OFF
OFF
2500
2500
ON
ON
OFF
ON
2880
2880
ON
ON
ON
OFF
4096
250
ON
ON
ON
ON
4096
4096
1)
For PPR postquadrature, multiply by 4.
2)
Hardware/Software Revision can be found on the dataplate label attached to the plastic cover of the module. For
example, the revision in the example below is 1B11.
SETTING THE DIP SWITCHES
To change the DIP SWITCH SETTING
1) Loosen the three set screws on the module
2) Detach the PCB board from the plastic cover
3) Change the SW1 positions according to the table above
4) Put the PCB board back in the plastic cover
5) Tighten the three set screws