CANopen
6
Parameter setting
6-17
L
BA2175 EN 2.0
Process data telegram from controller
User data length: 8 byte
Byte 1
Byte 2
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Byte 8
Identifier
Status word
L-C0150
Low byte
Status word
L-C0150
High byte
Actual value
L-C0050
Low byte
Actual value
L-C0050
High byte
xx
xx
xx
xx
Byte 1
Bits 0 to 7 of the status word under L-C0150 are entered here
M
i f
ti
Byte 2
Bits 8 to 15 of the status word under L-C0150 are entered here (seen chapter 6.3.4.2).
The bit description can be obtained from the Code Table.
More information
about the process
Byte 3
Actual frequency value with signed normalisation (L-C0050)
about the process
data
Byte 4
Actual frequency value with signed normalisation (L C0050)
24000 = 480 Hz is provided here.
data
telegram:
Byte 5
telegram:
Byte 6
No evaluation of these data anything possible
Byte 7
No evaluation of these data, anything possible
Byte 8
Status word: see chapter 6.3.4.2.
16 bit
16 bit
.B15
.B12
.B0
.B1
.B2
.B3
.B4
.B8
.B9
.B10
.B11
.B13
.B14
.B5
.B6
.B7
IMP
fd=fdset / RFG
Qmin
Imax
- / fd=fdset
PAR
fd>0
Ctrl. inhibit
Ugmax
CW/CCW
RDY
T ü
AIF
C0050
Status
word
Controller
status
+/-24.000 = +/- 480Hz
2141LON012
Fig. 6-4
Read access to status word and actual frequency value in 82XX (fixed, see (
^
6-21) )
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.actechdrives.com - Email: [email protected]