Figure 24. Connecting cables from the RAID card to the backplanes
To connect the mini-SAS signal cables from the RAID card to the backplanes, do the following:
• If you are using a ThinkServer RAID 700 Adapter, do the following:
1. Use one mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
3
on one end of the
cable to the ports 3-0 on the RAID card. Then, connect the mini-SAS connector
4
on the other
end of the cable to the mini-SAS signal cable connector 0 on the backplane for 2.5-inch hard disk
drives or to the mini-SAS signal cable connector on the backplane for 3.5-inch hard disk drives. The
backplane for 3.5-inch hard disk drives is installed on the lower hard-disk-drive cage.
2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS signal
cable. Connect the mini-SAS connector
1
on one end of the cable to the ports 7-4 on the RAID
card. Then, connect the mini-SAS connector
2
on the other end of the cable to the mini-SAS signal
cable connector 1 on the backplane for 2.5-inch hard disk drives or to the mini-SAS signal cable
connector on the backplane for 3.5-inch hard disk drives. The backplane for 3.5-inch hard disk drives
is installed on the upper hard-disk-drive cage.
• If you are using a ThinkServer RAID 500 Adapter, do the following:
1. Use one mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector
1
on one end of the
cable to the port 0 on the RAID card. Then, connect the mini-SAS connector
2
on the other end of
the cable to the mini-SAS signal cable connector 0 on the backplane for 2.5-inch hard disk drives or
to the mini-SAS signal cable connector on the backplane for 3.5-inch hard disk drives. The backplane
for 3.5-inch hard disk drives is installed on the lower hard-disk-drive cage.
2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS signal
cable. Connect the mini-SAS connector
3
on one end of the cable to the port 1 on the RAID card.
Then, connect the mini-SAS connector
4
on the other end of the cable to the mini-SAS signal
cable connector 1 on the backplane for 2.5-inch hard disk drives or to the mini-SAS signal cable
connector on the backplane for 3.5-inch hard disk drives. The backplane for 3.5-inch hard disk drives
is installed on the upper hard-disk-drive cage.
Note:
The location of the external connector on the RAID card differs depending on the type of RAID card.
38
ThinkServer TS440 Hardware Maintenance Manual
Содержание ThinkServer TS440 70AL
Страница 1: ...ThinkServer TS440 Hardware Maintenance Manual Machine Types 70AL 70AM 70AN and 70AQ ...
Страница 16: ...4 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 18: ...6 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 41: ...Figure 14 3 5 inch hot swap hard disk drive status LEDs Chapter 3 Product overview 29 ...
Страница 58: ...46 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 76: ...64 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 188: ...176 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 201: ......
Страница 202: ......