4. The non-hot-swap hard disk drives are installed in the lower hard-disk-drive cage and are protected
by an EMI-protective panel. Press the small tab
1
on the EMI-protective panel from the bottom, and
then pivot the EMI-protective panel upward to remove it from the chassis and gain access to the
non-hot-swap hard-disk-drive bays.
Figure 50. Removing the EMI-protective panel
5. Remove the front system fan 1. See “Replacing the front system fan 1” on page 144.
6. Locate the non-hot-swap hard-disk-drive bay. See “Server components” on page 23.
7. Touch the static-protective package that contains the new non-hot-swap hard disk drive to any
unpainted surface on the outside of the server. Then, take the new non-hot-swap hard disk drive and
the signal cable out of the package.
Note:
Do not touch the circuit board on the hard disk drive.
Chapter 6
.
Installing, removing, or replacing hardware