To install or replace an internal RDX drive, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 67.
3. Locate the optical drive bay where you want to install or replace the RDX drive. See “Server
components” on page 23.
4. Depending on whether you are installing or replacing an RDX drive, do one of the following:
• If you are installing an RDX drive, remove the front bezel. See “Removing and reinstalling the front
bezel” on page 69. Then, remove the plastic shield for the bay from the front panel. Remove the
screw
1
that secures the metal EMI shield covered on the optical drive bay. Insert a finger into the
hole in the EMI shield and carefully pull the EMI shield out of the front of the chassis.
Figure 58. Removing the EMI shield for the upper optical drive bay
104
ThinkServer TS440 Hardware Maintenance Manual