• The front panel board assembly is sensitive to ESD. Ensure that you read and understand “Handling
static-sensitive devices” on page 66 first and carefully perform the operation.
To replace the front panel board assembly, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 67.
3. Remove the front bezel. See “Removing and reinstalling the front bezel” on page 69.
4. Locate the front panel. See “Front panel” on page 16.
5. Remove the front system fans. See “Replacing the front system fan 1” on page 144.
6. Disconnect the signal cables of the front panel board assembly from the front USB 3.0 connector, the
front panel connector, and the thermal sensor connector on the system board. See “System board
components” on page 39.
7. If necessary, remove any parts or disconnect any cables that might impede your access to the signal
cables of the front panel board assembly. Record the cable routing, and then release the signal cables
of the front panel board assembly from any cable clips or ties in the chassis.
8. Remove the screw
1
on the chassis that secures the front panel board assembly. Then, carefully
remove the front panel board assembly from the chassis and pull the signal cables of the front panel
board assembly out of the chassis.
Figure 99. Removing the front panel board assembly
9. Touch the static-protective package that contains the new front panel board assembly to any unpainted
surface on the outside of the server. Then, take the new front panel board assembly out of the package.
10. Record the cable connection. Then, disconnect the signal cables from the rear of the old front panel
board assembly and connect them to the rear of the new one.
Chapter 6
.
Installing, removing, or replacing hardware
143
Содержание ThinkServer TS440 70AL
Страница 1: ...ThinkServer TS440 Hardware Maintenance Manual Machine Types 70AL 70AM 70AN and 70AQ ...
Страница 16: ...4 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 18: ...6 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 41: ...Figure 14 3 5 inch hot swap hard disk drive status LEDs Chapter 3 Product overview 29 ...
Страница 58: ...46 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 76: ...64 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 188: ...176 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 201: ......
Страница 202: ......