6. Slide the new RDX drive into the optical drive bay from the front until it snaps into position.
Note:
You do not need to remove the front bezel when replacing an RDX drive. However, if you are
installing an RDX drive, you need to remove the front bezel first, and then gain access to the protective
shields to remove them. The following illustration shows only the situation in which the front bezel has
been removed.
Figure 60. Installing the RDX drive
7. Connect the 4-pin power cable
1
and the signal cable
2
to the rear of the RDX drive.
Figure 61. Connecting cables to the rear of the RDX drive
8. If necessary, connect the USB connector on the other end of the signal cable
2
to the USB 2.0
connector on the system board. See “System board components” on page 39.
9. If necessary, connect the 4-pin power connector on one end of the optical drive power cable to the
corresponding 4-pin power connector on the system board. Then, connect the power connector on the
other end of the power cable
1
to one of the power connectors on the other end of the optical drive
power cable. See “System board components” on page 39.
10. Reinstall the front bezel. See “Removing and reinstalling the front bezel” on page 69.
106
ThinkServer TS440 Hardware Maintenance Manual
Содержание ThinkServer TS440 70AL
Страница 1: ...ThinkServer TS440 Hardware Maintenance Manual Machine Types 70AL 70AM 70AN and 70AQ ...
Страница 16: ...4 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 18: ...6 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 41: ...Figure 14 3 5 inch hot swap hard disk drive status LEDs Chapter 3 Product overview 29 ...
Страница 58: ...46 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 76: ...64 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 188: ...176 ThinkServer TS440 Hardware Maintenance Manual ...
Страница 201: ......
Страница 202: ......