8. To install a new tertiary hard disk drive, see “Installing the tertiary hard disk drive” on page 51.
What to do next:
• To work with another piece of hardware, go to the appropriate section.
• To complete the removal procedure, go to “Completing the parts replacement” on page 90.
Installing or removing the slim optical drive and the fourth hard disk drive
This topic provides instructions on how to install or remove the slim optical drive and the fourth hard disk
drive.
Note:
For a 2.5-inch hard disk drive or solid-state drive, install the drive into a 3.5-inch to 2.5-inch drive
adapter first. See “Installing the 2.5-inch solid-state drive or hard disk drive” on page 49.
Installing the slim optical drive and the fourth hard disk drive
Attention:
Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii and “Guidelines” on page 39.
You can install a slim optical drive and a fourth hard disk drive into the optical drive bay of your server.
This topic provides instructions on how to install the slim optical drive and the fourth hard disk drive into the
optical drive bay.
To install the slim optical drive and the fourth hard disk drive, do the following:
1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all
power cords from electrical outlets and disconnect all cables that are connected to the server.
2. Remove the server cover. See “Removing the server cover” on page 41.
3. Remove the front bezel. See “Removing and reinstalling the front bezel” on page 42.
4. Install the slim optical drive conversion board into the cage for the slim optical drive and the fourth hard
disk drive. Then, install the two screws to secure the slim optical drive conversion board.
Figure 25. Installing the slim optical drive conversion board
56
ThinkServer TS140 Hardware Maintenance Manual
Содержание ThinkServer TS140
Страница 1: ...ThinkServer TS140 Hardware Maintenance Manual Machine Types 70A0 70A1 70A4 and 70A5 ...
Страница 14: ...xii ThinkServer TS140 Hardware Maintenance Manual ...
Страница 18: ...4 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 20: ...6 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 34: ...20 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 36: ...22 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 52: ...38 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 112: ...Symptom Action 2 Restart the server 3 Replace the USB device 98 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 116: ...102 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 130: ...116 ThinkServer TS140 Hardware Maintenance Manual ...
Страница 131: ......
Страница 132: ......