v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints,
tips, and new device drivers or to submit a request for information.
Error code
Description
Action
2018001
PCI Express uncorrected or uncorrected error
1.
Check the riser-card LEDs.
2.
Reseat all affected adapters and riser cards.
3.
Update the PCI adapter firmware.
4.
Remove the adapter from the riser card.
5.
Replace the following components one at a time,
in the order shown, restarting the server each
time:
a.
Riser card
b.
(Trained service technician only) System board
2018002
Option ROM resource allocation failure
Informational message that some devices might not
be initialized.
1.
If possible, rearrange the order of the adapters in
the PCI slots to change the load order of the
optional-device ROM code.
2.
Run the Setup utility, select
Startup Options
, and
change the boot priority to change the load order
of the optional-device ROM code.
3.
Run the Setup utility and disable some other
resources, if their functions are not being used, to
make more space available.
a.
Select
Startup Options
→
Planar Ethernet
(PXE/DHCP)
to disable the integrated
Ethernet controller ROM.
b.
Select
Advanced Functions
→
PCI Bus Control
→
PCI ROM Control Execution
to disable the
ROM of the adapter in the PCI slots.
c.
Select
Devices and I/O Ports
to disable any of
the integrated devices.
4.
Replace the following components one at a time,
in the order shown, restarting the server each
time:
a.
Each adapter
b.
(Trained service technician only) System board
3
xx
0007 (
xx
can be 00 -
19)
Firmware fault detected, system halted
1.
Recover the server firmware to the latest level.
2.
Undo any recent configuration changes, or clear
CMOS memory to restore the settings to the
default values (see Table 6 on page 111).
3.
Remove any recently installed hardware.
Chapter 4. Diagnostics
25
Содержание ThinkServer 6531
Страница 1: ...Hardware Maintenance Manual ThinkServer RS210 Machine Types 6531 6532 6533 and 6534 ...
Страница 2: ......
Страница 3: ...ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 22: ...14 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 184: ...176 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 206: ...198 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 237: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 229 ...
Страница 238: ...230 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 243: ......
Страница 244: ...Part Number XXXXXX Printed in USA 1P P N XXXXXX ...