b.
In the location from which you removed the failed fan, route the fan cable into its slot
2
in the
fan bracket top.
c.
Insert the fan
4
into the bracket
3
.
d.
Make sure that each of the grey soft tabs on the fan is fully seated in its slot in the fan bracket.
3.
Connect the replacement fan cable to the system board.
4.
Go to “Completing the FRU replacement” on page 173.
Replacing the system-board battery
To replace the system-board battery, complete the following procedures:
Removing the battery
To remove the battery, complete the following steps.
1.
Read the safety information in “Important Safety Information” on page 1 and “Guidelines for trained
service technicians” on page 115.
2.
Turn off the server and peripheral devices, and disconnect the power cords and all external cables.
3.
Remove the cover (see “Removing and installing the cover” on page 119).
4.
If necessary, lift the riser-card assembly out of the way (see “Removing the riser-card assembly” on
page 157).
5.
Remove the battery:
Chapter 6. Replacing FRUs
151
Содержание ThinkServer 6531
Страница 1: ...Hardware Maintenance Manual ThinkServer RS210 Machine Types 6531 6532 6533 and 6534 ...
Страница 2: ......
Страница 3: ...ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 22: ...14 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 184: ...176 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 206: ...198 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 237: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 229 ...
Страница 238: ...230 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 243: ......
Страница 244: ...Part Number XXXXXX Printed in USA 1P P N XXXXXX ...