Table 5. DSA Preboot messages (continued)
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v
See Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a Trained service
technician.
v
Go to the Lenovo support Web site at http://www.lenovo.com/support to check for technical information, hints, tips, and new
device drivers or to submit a request for information.
Message
number
Component
Test
State
Description
Action
405-906-xxx
BroadCom
Ethernet
Device
Test Loop
back at
Physical
Layer
Failed
1.
Check the Ethernet cable for damage and make
sure that the cable type and connection are
correct.
2.
Make sure that the component firmware is at the
latest level. The installed firmware level is shown
in the DSA event log in the Firmware/VPD
section for this component. For more information,
see “Updating the firmware” on page 212.
3.
Run the test again.
4.
Replace the component that is causing the error. If
the error is caused by an adapter, replace the
adapter. Check the PCI Information and Network
Settings information in the DSA event log to
determine the physical location of the failing
component.
5.
If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support..
405-907-xxx
BroadCom
Ethernet
Device
Test Loop
back at
MAC-Layer
Failed
1.
Make sure that the component firmware is at the
latest level. The installed firmware level is shown
in the DSA event log in the Firmware/VPD
section for this component. For more information,
see “Updating the firmware” on page 212.
2.
Run the test again.
3.
Replace the component that is causing the error. If
the error is caused by an adapter, replace the
adapter. Check the PCI Information and Network
Settings information in the DSA event log to
determine the physical location of the failing
component.
4.
If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support..
405-908-xxx
BroadCom
Ethernet
Device
Test LEDs
Failed
1.
Make sure that the component firmware is at the
latest level. The installed firmware level is shown
in the DSA event log in the Firmware/VPD
section for this component. For more information,
see “Updating the firmware” on page 212.
2.
Run the test again.
3.
Replace the component that is causing the error. If
the error is caused by an adapter, replace the
adapter. Check the PCI Information and Network
Settings information in the DSA event log to
determine the physical location of the failing
component.
4.
If the failure remains, go to the Lenovo Web site
for more troubleshooting information at
http://www.lenovo.com/support..
Chapter 4. Diagnostics
99
Содержание ThinkServer 6531
Страница 1: ...Hardware Maintenance Manual ThinkServer RS210 Machine Types 6531 6532 6533 and 6534 ...
Страница 2: ......
Страница 3: ...ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 22: ...14 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 184: ...176 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 206: ...198 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 237: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 229 ...
Страница 238: ...230 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 243: ......
Страница 244: ...Part Number XXXXXX Printed in USA 1P P N XXXXXX ...