v
Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v
See Chapter 7, “Parts listing, RS210 Types 6531, 6532, 6533, and 6534,” on page 177 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Array %1 is in critical condition.
(%1 = CIM_ComputerSystem.
ElementName)
Error
An array is in Critical state.
(Sensor = Drive
n
Status)
(
n
= hard disk drive
number)
Replace the hard disk drive that
is indicated by a lit status LED.
Array %1 has failed.
(%1 = CIM_ComputerSystem.
ElementName)
Error
An array is in Failed state.
(Sensor = Drive
n
Status)
(
n
= hard disk drive
number)
Replace the hard disk drive that
is indicated by a lit status LED.
Memory uncorrectable error detected
for DIMM All DIMMs on Memory
Subsystem All DIMMs.
Error
A memory uncorrectable
error has occurred.
1.
If the server failed the POST
memory test, reseat the
DIMMs.
2.
Replace any DIMM that is
indicated by a lit error LED.
Note:
You do not have to
replace DIMMs by pairs.
3.
Run the Setup utility to
enable all the DIMMs.
4.
Run the DSA memory test.
Memory Logging Limit Reached for
DIMM All DIMMs on Memory
Subsystem All DIMMs.
Error
The memory logging limit
has been reached.
1.
Update the server firmware to
the latest level.
Important:
Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify
that the latest level of code is
supported for the cluster
solution before you update
the code.
2.
Reseat the DIMMs and run
the DSA memory test.
3.
Replace any DIMM that is
indicated by a lit error LED.
Memory DIMM Configuration Error
for All DIMMs on Memory
Subsystem All DIMMs.
Error
A DIMM configuration error
has occurred.
Make sure that DIMMs are
installed in the correct sequence
and have the same size, type,
speed, and technology.
Memory uncorrectable error detected
for DIMM One of the DIMMs on
Memory Subsystem One of the
DIMMs.
Error
A memory uncorrectable
error has occurred.
1.
If the server failed the POST
memory test, reseat the
DIMMs.
2.
Replace any DIMM that is
indicated by a lit error LED.
Note:
You do not have to
replace DIMMs by pairs.
3.
Run the Setup utility to
enable all the DIMMs.
4.
Run the DSA memory test.
38
ThinkServer ThinkServer RS210, Types 6531, 6532, 6533, and 6534: Hardware Maintenance Manual
Содержание ThinkServer 6531
Страница 1: ...Hardware Maintenance Manual ThinkServer RS210 Machine Types 6531 6532 6533 and 6534 ...
Страница 2: ......
Страница 3: ...ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 22: ...14 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 184: ...176 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 206: ...198 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 237: ...People s Republic of China Class A warning statement Korea Class A warning statement Appendix Notices 229 ...
Страница 238: ...230 ThinkServer ThinkServer RS210 Types 6531 6532 6533 and 6534 Hardware Maintenance Manual ...
Страница 243: ......
Страница 244: ...Part Number XXXXXX Printed in USA 1P P N XXXXXX ...