2. If system boots to F1 setup, update the UEFI image and reset bank to primary (if required). If the
system boots without error, recovery is complete and no additional action is required.
3. If system fails to boot, or if the firmware update attempt fails, (trained service technician only)
replace the system board.
•
I.3818009 [I.3818009]
Explanation:
The TPM could not be properly initialized. TPMINIT: Fail to initialize TPM chip.
Severity
Info
User Response
Complete the following steps:
1. Check the Lenovo support site for an applicable service bulletin or firmware update that applies
to this error.
2. Reboot the system.
3. If the error continues, replace the system-board assembly (see Removing the system-board
assembly and Installing the system-board assembly).
•
I.3868000 [I.3868000]
Explanation:
IFM: System reset performed to reset adapters. IFM: System reset performed to reset
adapters
Severity
Info
User Response
Complete the following steps:
1. Information only; no action is required.
•
I.3868003 [I.3868003]
Explanation:
IFM: Configuration to large for compatibility mode. IFM: Configuration too large for
compatibility mode
Severity
Info
User Response
Complete the following steps:
1. Information only; no action is required.
•
I.5100B [I.5100B]
Explanation:
An unqualified DIMM serial number has been detected: serial number % found in slot % of
memory card %. Unqualified DIMM Serial Number Detected
Severity
Info
User Response
Complete the following steps:
1. If this information event is logged in the IMM event log, the server does not have qualified
memory installed.
2. The memory installed may not be covered under warranty.
3. Without qualified memory, speeds supported above industry standards will not be enabled.
4. Please contact your Local Sales Representative or Authorized Business Partner to order
qualified memory to replace the unqualified DIMM(s).
698
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide
Содержание NeXtScale n1200
Страница 115: ...Chapter 6 Removing and replacing server components 101 ...
Страница 117: ...Chapter 6 Removing and replacing server components 103 ...
Страница 119: ...Chapter 6 Removing and replacing server components 105 ...
Страница 135: ...Chapter 6 Removing and replacing server components 121 ...
Страница 137: ...Chapter 6 Removing and replacing server components 123 ...
Страница 139: ...Chapter 6 Removing and replacing server components 125 ...
Страница 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Страница 877: ......
Страница 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...