AC power
LED (green)
DC power
LED (green)
Power-supply
error LED (yellow)
Figure 7. Power supply front view
The power supplies get electrical power from a 100 - 127 V ac or 200 - 240 V ac power source and convert
the ac input into 12 V outputs. The power supplies are capable of autoranging within the input voltage range.
There is one common power domain for the chassis that distributes power to each of the water-cooled
technology trays and modules through the system midplane.
AC redundancy is achieved by distributing the ac power cord connections between independent ac circuits.
When applying the power supplies redundancy policy through fan and power controller after the water-
cooled technology trays are powered on, it may not be sufficient to allow N+1 or N+N configuration at
current power supplies redundancy state. Before you change the power supplies redundancy policy, you
may use the Power Configurator utility to determine current system power consumption. For more
information and to download the utility, go to http://www-03.ibm.com/systems/bladecenter/resources/
powerconfig.html.
Each power supply has internal fans and a controller. The power supply controller can be powered by any
installed power supply that is providing power through the midplane.
Attention:
The power supplies contain internal cooling fans. Do not obstruct the fan exhaust vents.
You have to install all of the six power supplies regardless of the type of power supply, the chassis power
load, or selected chassis power policy.
The NeXtScale nx360 M5 water-cooled technology tray does not support mixing of low input voltage power
supplies with high input voltage power supplies. For example, if you install a power supply with an input
voltage of 100 - 127 V ac in a chassis that is powered by 200 - 240 V ac power supplies, the 100 - 127 V
power supply will not power on. The same restriction applies to a chassis that is powered by 100 - 127 V ac
power supplies. If you install a 200 - 240 V ac power supply in a chassis that is powered by 100 - 127 V ac
power supplies, the 200 - 240 V ac power supply will not power on.
Power supply controls and indicators
There are three LEDs on each power supply:
18
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide
Содержание NeXtScale n1200
Страница 115: ...Chapter 6 Removing and replacing server components 101 ...
Страница 117: ...Chapter 6 Removing and replacing server components 103 ...
Страница 119: ...Chapter 6 Removing and replacing server components 105 ...
Страница 135: ...Chapter 6 Removing and replacing server components 121 ...
Страница 137: ...Chapter 6 Removing and replacing server components 123 ...
Страница 139: ...Chapter 6 Removing and replacing server components 125 ...
Страница 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Страница 877: ......
Страница 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...