Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix:
PLAT
ID:
0142
User Response
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
•
806f090c-2009ffff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled. (DIMM 9)
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c2009ffff or 0x806f090c2009ffff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
22
CIM Information
Prefix:
PLAT
ID:
0142
User Response
1. Reseat the DIMM, and then restart the server.
2. Replace DIMM n. (n = DIMM number)
•
806f090c-200affff : [PhysicalMemoryElementName] on Subsystem [MemoryElementName]
Throttled. (DIMM 10)
This message is for the use case when an implementation has detected Memory has been Throttled.
May also be shown as 806f090c200affff or 0x806f090c200affff
Severity
Warning
Serviceable
Yes
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
488
Lenovo NeXtScale nx360 M5 water-cooled technology tray Lenovo NeXtScale n1200 Enclosure Installation and Service Guide
Содержание NeXtScale n1200
Страница 115: ...Chapter 6 Removing and replacing server components 101 ...
Страница 117: ...Chapter 6 Removing and replacing server components 103 ...
Страница 119: ...Chapter 6 Removing and replacing server components 105 ...
Страница 135: ...Chapter 6 Removing and replacing server components 121 ...
Страница 137: ...Chapter 6 Removing and replacing server components 123 ...
Страница 139: ...Chapter 6 Removing and replacing server components 125 ...
Страница 869: ...Taiwan Class A compliance statement Appendix E Notices 855 ...
Страница 877: ......
Страница 878: ...Part Number SP47A31725 Printed in China 1P P N SP47A31725 1PSP47A31725 ...